The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Aluminum Chemistry in a Prototypical Post-Loss-of-Coolant-Accident, Pressurized-Water-Reactor Containment Environment (NUREG/CR-6915)
On this page:
Download complete document
Publication Information
Manuscript Completed: August 2006
Date Published: December 2006
Principal Investigator: M. Klasky
Prepared by:
M. Klasky, J. Zhang, M. Ding, and B. Letellier (Los Alamos National Laboratory)
D. Chen and K. Howe (University of New Mexico)
Los Alamos National Laboratory
Los Alamos, NM 87545
University of New Mexico
Department of Civil Engineering
Albuquerque, NM 87110
T.Y. Chang, NRC Project Manager
Prepared for:
Division of Fuel, Engineering and Radiological Research
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC Job Code N6285
Abstract
An analysis of the integrated chemical effects tests (ICET) experiments has been performed by a comprehensive examination of both the test solutions and precipitates. In addition, a comprehensive review of the literature has been performed to assist in explaining the behavior of aluminum in alkaline solutions. The objective of this analysis was to elucidate the behavior of precipitate that formed when the ICET Tests 1 and 5 solutions were allowed to cool so that the behavior of other solutions with different conditions, i.e., pH, temperature, etc., could be predicted throughout the pressurized water reactor following a loss-of-coolant accident (LOCA). This examination included supplemental analytical measurements using x-ray diffraction, 27Al and 11B nuclear magnetic resonance for both liquid and solid states, and quasi-elastic light-scattering measurements. Surrogate solutions were developed and compared with the analytical measurements of the ICET Tests 1 and 5 solutions. Finally, the characterization of the particle sizes and corrosion properties, including the corrosion mechanism and the corrosion rate of aluminum under LOCA conditions, has been elucidated. The current study should allow for the development of a head-loss correlation using the existing cake filtration theory, which could be used in conjunction with a corrosion model to predict system performance following a LOCA.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021