Age-Specific Inhalation Radiation Dose Commitment Factors for Selected Radionuclides (NUREG/CR-2384, PNL-3912)
On this page:
Download complete document
Publication Information
Manuscript Completed: July 1982
Date Published: August 1982
Prepared by:
D. L. Strenge, R. A. Peloquin, D. A. Baker
Pacific Northwest Laboratory
Richland, WA 99352
Prepared for:
Division of Fuel Cycle and Material Safety
Office of Nuclear Material Safety and Safeguards
US Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC FIN 82218
Availability Notice
Abstract
Inhalation dose commitment factors are presented for selected radionuclides for exposure of individuals in four age groups: infant, child, teen and adult. Radionuclides considered are 35S, 36Cl, 45Ca, 67Ga, 75Se, 85Sr, 109Cd, 113Sn, 125I, 133Ba, 170Tm, 169Yb, 182Ta, 192Ir, 198Au, 201Tl, 204Tl, and 236Pu. The calculational method is based on the human metabolic model of ICRP as defined in Publication 2 (ICRP 1959) and as used in previous age-specific dose factor calculations by Hoenes and Soldat (1977). Dose commitment factors are presented for the following organs of reference: total body, bone, liver, kidney, thyroid, lung and lower large intestine.