The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Proceedings of the International Workshop on Conceptual Model Development for Subsurface Reactive Transport Modeling of Inorganic Contaminants, Radionuclides, and Nutrients: … Albuquerque, New Mexico, April 20–24, 2004 (NUREG/CP-0193)
On this page:
Download complete document
Publication Information
Manuscript Completed: November 2005
Date Published: March 2006
Workshop Sponsored by:
Interagency Steering Committee on Multimedia Environmental Models (ISCMEM)
Workshop Organized and Convened by:
Federal Working Group on Subsurface Reactive Solute Transport Modeling
Proceedings Prepared by:
R.T. Cygan, M.D. Siegel, and L.J. Criscenti
Sandia National Laboratories
Albuquerque, NM 87185-0754
Edward O'Donnell, NRC Project Manager
Proceedings Prepared for:
Division of Systems Analysis and Regulatory Effectiveness
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
An international workshop on Conceptual Model Development for Subsurface Reactive Transport Modeling of Inorganic Contaminants, Radionuclides, and Nutrients was held April 20-24, 2004 at La Posada de Albuquerque in Albuquerque, New Mexico. The workshop was organized and convened by the Federal Working Group on Subsurface Reactive Solute Transport Modeling and sponsored by the Federal Interagency Steering Committee on Multimedia Environmental Models (ISCMEM). The workshop themes were organized by processes: physical properties/coupling, sorption, precipitation/dissolution, and redox/microbiology. The workshop objectives were to 1) evaluate the state-of-the-art in conceptual model development and parameterization for reactive transport modeling as applied to soil, vadose zone, and groundwater systems and 2) prioritize research directions that would enhance the practical utility of reactive transport modeling. Plenary presentations and discussions provided an overview of critical modeling issues and needs, various agency applications, specifics of the four primary themes, and examples of complex applications of reactive transport models. Breakout discussion groups generated reports summarizing the motivation, current state-of-the-science, expectations, and recommendations for research in each of the four theme topics.
Page Last Reviewed/Updated Tuesday, September 02, 2025
Page Last Reviewed/Updated Tuesday, September 02, 2025