The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Simulations of the BEAVRS PWR with SCALE and PARCS (NUREG/IA-0529)
On this page:
Download complete document
Publication Information
Manuscript Completed: December 2021
Date Published: December 2022
Prepared by:
Piotr Darnowski, Michal Pawluczyk
Warsaw University of Technology,
Faculty of Power and Aeronautical Engineering,
Institute of Heat Engineering,
Nowowiejska 21/25,
00-665 Warsaw, Poland
K. Tien
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)
Abstract
The first fuel cycle of the BEAVRS PWR benchmark was simulated and analyzed. Models were prepared using the SCALE package, TRITON depletion sequence and NEWT as a lattice physics solver. A set of branch and burnup calculations were prepared, and group constants in the form of PMAXS libraries were generated using GenPMAXS for PARCS nodal diffusion core simulator. The hot zero power reactor physics measurement data and hot full power data were used to perform model validation simulations for the 1st fuel cycle. The core inventories for the BOC and EOC were calculated on the basis of PARCS and TRITON results with a dedicated computer code and compared with ORIGEN-ARP point burnup calculations.
Page Last Reviewed/Updated Monday, December 12, 2022
Page Last Reviewed/Updated Monday, December 12, 2022