The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
TRACE VVER-1000/V-320 Model Validation (NUREG/IA-0490)
On this page:
Download complete document
Publication Information
Manuscript Completed: March 2017
Date Published: December 2018
Prepared by:
S. Iegan, A. Mazur, Y. Vorobyov, O. Zhabin, S. Yanovskiy
State Nuclear Regulatory Inspectorate of Ukraine
and
State Scientific and Technical Center
for Nuclear and Radiation Safety of Ukraine
9/11 Arsenalna str.
Kyiv, Ukraine 01011
K. Tien, NRC Project Manager
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)
Published by:
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
This report is developed by the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) and its technical support organization, the State Scientific and Technical Center for Nuclear and Radiation Safety of Ukraine (SSTC NRS), under Implementing Agreement On Thermal-Hydraulic Code Applications And Maintenance Between The United States Nuclear Regulatory Commission and State Nuclear Regulatory Inspectorate of Ukraine (signed in 2014) in accordance with Article III, Section C, of the Agreement.
The report provides results of the validation calculations conducted with application of SSTC NRS model of VVER-1000/V-320 unit for TRACE computer code. The calculation scenarios simulate actual incidents that occurred at Ukrainian NPPs.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021