Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

RELAP5/MOD3.3 Assessment against PMK Test T3.1 – LBLOCA with Nitrogen in PRZ (NUREG/IA-0246)

On this page:

Download complete document

Publication Information

Manuscript Completed: November 2008
Date Published: October 2010

Prepared by:
Pavel Kral

Nuclear Research Institute Rez
Husinec-Rez 130
250 68 Rez, Czech Republic

A. Calvo, NRC Project Manager

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the International Code Assessment and Maintenance Program (CAMP)

Prepared for:
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

The results of RELAP5 post-test analyses of test T3.1 performed on the PMK experimental facility are presented. The Hungarian facility PMK is a scaled-down model of NPP with VVER-440/213 reactor. The code versions RELAP5/MOD3.3hg (post Patch03) and RELAP5/MOD3.3ef (Patch02) have been assessed against the experimental data from the test T3.1. The test T3.1 was a large-break LOCA with 30% break starting from shutdown conditions with nitrogen in PRZ. Generally, both prediction of system behavior and prediction of nitrogen transport are in very good agreement with measured data.

Page Last Reviewed/Updated Tuesday, March 09, 2021

Page Last Reviewed/Updated Tuesday, March 09, 2021