Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Experimental Study of Narrow Pulse Effects on the Behavior of High Burnup Fuel Rods with Zr-1%Nb Cladding & UO 2 Fuel under Reactivity-Initiated Accident Conditions: Test Conditions and Results (NUREG/IA-0213, Volume 2, IRSN/DPAM2005-275, NSI RRC KI-3230)

On this page:

Download complete document

Publication Information

Date Published: March 2006

Prepared by:
L. Yegorova, K. Lioutov, N. Jouravkova
Nuclear Safety Institute of Russian Research Centre, "Kurchatov Institute"
Kurchatov Square 1
Moscow 123182, Russian Federation

O. Nechaeva, A. Salatov
A.A. Bochvar All-Russian Research Institute of Inorganic Materials
Rogov Street 5
Moscow 123182, Russian Federation

V. Smirnov, A. Goryachev
State Research Centre, "Research Institute of Atomic Reactors"
Dimitrovgrad 433510, Russian Federation

V. Ustinenko, I. Smirnov
Russian Federal Nuclear Centre, "All-Russian Research Institute of Experimental Physics"
Sarov 607200, Russian Federation

Prepared for:
U.S. Nuclear Regulatory Commission (United States)
Institute for Radiological Protection and Nuclear Safety (France)
Joint Stock Company "TVEL" (Russian Federation)

Published by:
Division of Systems Analysis and Regulatory Effectiveness
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

This volume of the report contains a detailed description of calculation and test results obtained in the fast-pulse-graphite-reactor (BIGR) tests of twelve fuel rods refabricated from the VVER-440 and VVER-1000 high burnup fuel elements (50, 60 MW d/kg U).

The BIGR data base includes the following types of fuel rod characterization:

  • material and geometrical parameters of VVER-440 and VVER-1000 commercial fuel elements before the base irradiation in the nuclear power plant (NPP);
  • parameters of fuel cycles and characteristics of commercial fuel elements after the base irradiation;
  • characteristics of twelve refabricated fuel rods before the BIGR pulse tests;
  • parameters of the BIGR power pulses;
  • characteristics of refabricated fuel rods during and after the BIGR tests.

Page Last Reviewed/Updated Tuesday, September 02, 2025

Page Last Reviewed/Updated Tuesday, September 02, 2025