United States Nuclear Regulatory Commission - Protecting People and the Environment

Assessment of the Turbine Trip Transient in Cofrentes NPP with TRAC–BF1 (NUREG/IA-0120, EST–SIAN–22)

On this page:

Download complete document

Publication Information

Date Published: June 1993

Prepared by:
F. Castrillo/Hidroelectrica Espanola (H.E.)
A. Gomez/Union Iberoamericana De Tecnologia (UITESA)
I. Gallego/Union Iberoamericana De Tecnologia (UITESA)

Unidad Electrica, S.A.
c/Francisco Gervas, 3
28020–Madrid, Spain

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Foreword

This report has been prepared by Hidroeléctrica Española in the framework of the ICAP-UNESA Project.

The report represents one of the application calculations submitted in fulfilment of the bilateral agreement for cooperation in thermalhydraulic activities between the Consejo de Seguridad Nuclear of Spain (CSN) and the United States Nuclear Regulatory Commission (USNRC) in the form of Spanish contribution to the International Code Assessment and Applications Program (ICAP) of the USNRC whose main purpose is the validation of the TRAC and RELAP system codes.

The Consejo de Seguridad Nuclear has promoted a coordinated Spanish Nuclear Industry effort (ICAP-SPAIN) aiming to satisfy the requirements of this agreement and to improve the quality of the technical support groups at the Spanish Utilities, Spanish Research Establishments, Regulatory Staff and Engineering Companies, for safety purposes.

This ICAP-SPAIN national program includes agreements between CSN and each of the following organizations:

- Unidad Eléctrica (UNESA)
- Unión Iberoamericana de Tecnología Eléctrica (UITESA)
- Empresa Nacional del Uranio (ENUSA)
- TECNATOM
- Empresarios Agrupados
- LOFT-ESPAÑA

The program is executed by 12 working groups and a generic code review group and is coordinated by the "Comité de Coordinación". This committee has approved the distribution of this document for ICAP purposes.

Page Last Reviewed/Updated Monday, February 03, 2020