The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Assessment of RELAP5/MOD2 Using the Test Data of REWET-II Reflooding Experiment SGI/R (NUREG/IA-0090)
On this page:
Download complete document
Publication Information
Date Published: May 1993
Prepared by:
A. Hämäläinen
Technical Research Centre of Finland
Nuclear Engineering Laboratory
P.O. Box 169
SF-00181 Helsinki, Finland
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
An analyses of a reflooding experiment with RELAP5/MOD2 cycle 36.04 is presented. The experiment had been carried out in the REWET-II facility simulating the reactor core with a bundle of 19 electrically heated rods. On the basis of the results of two calculations recommendations for the core nodalization are presented, and a modification to the code is proposed.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021