The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Assessment of the "One Feedwater Pump Trip Transient" in Cofrentes Nuclear Power Plant With TRAC–BF1 (NUREG/IA-0068, ICSP–CO–TURFW–T)
On this page:
Download complete document
Publication Information
Date Published: April 1992
Prepared by:
F. Castrillo, Hidroelectrica Española
A. G. Navarro, I. Gallego, Union Iberoamericana De Tecnologia
Hidroelectrica Española
Hermosilla, 3
28001-Madrid
Spain
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Foreword
This report has been prepared by Hidroelectrica Española in the framework of the ICAP-UNESA Project.
The report represents one of the assessment calculations submitted in fulfilment of the bilateral agreement for cooperation in thermal-hydraulic activities between the Consejo de Seguridad Nuclear of Spain (CSN) and the United States Nuclear Regulatory Comission (NRC), in the form of Spanish contribution to the International Code Assessment and Applications Program (ICAP) of the US-NRC, whose main purpose is the validation of the TRAC and RELAP system codes.
The Consejo de Seguridad Nuclear has promoted a coordinated Spanish Nuclear Industry effort (ICAP-SPAIN) aiming to satisfy the requirements of this agreement and to improve the quality of the technical support groups at the Spanish Utilities, Spanish Research Establishments, Regulatory Staff and Engineering Companies, for Safety purposes.
This ICAP-SPAIN national program includes agreements between CSN and each of the following organizations:
- Unidad Eléctrica (UNESA)
- Unión Iberoamericana de Tecnologia Eléctrica (UITESA)
- Empresa Nacional del Uranio (ENUSA)
- TECNATOM
- LOFT-ESPAÑA
The program is executed by 12 working groups and a generic code review group, and is coordinated by the "Comité de Coordinacion". This comitee has aproved the distribution of this document for ICAP purposes.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021