Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Assessment of TRAC-PD2 Using SUPER CANNON and HDR Experimental Data (NUREG/IA-0001)

On this page:

Download complete document

Publication Information

Date Published: August 1986

Prepared by:
U. Neumann

Kraftwerk Union
Hammerbacherstr. 12+ 14
Postfach 3220
8520 Erlangen, The Federal Republic of Germany

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555

Availability Notice

Abstract

This report assesses the predictive capabilities of the Transient Reactor Analysis Code (TRAC-PD2) using data from the SUPER CANON and HEISS DAMPF REACTOR (HDR) experimental facilities. The report is divided into three parts. Part I is the TRAC-PD2 assessment using SUPER CANON data. Part II is the TRAC-PD2 assessment using HDR data. Part III provides recommendations for the user using the combined assessment results. In general, it is shown that the TRAC-PD2 predictions were in good agreement with the actual test pressures and and mass flow rates for both these tests. TRAC-PD2 provided considerably better results than TRAC-P1A. This was particularly true with regard to sound velocity predictions which play a significant role whenever the speed of pressure relief waves must be determined.

Page Last Reviewed/Updated Tuesday, March 09, 2021

Page Last Reviewed/Updated Tuesday, March 09, 2021