Information Notice No. 81-26, Part 3, Supplement No. 1: Clarification of Placement of Personnel Monitoring Devices for External Radiation
SSINS No.: 6835
IN 81-26, Part 3, Sup. No. 1
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
July 19, 1982
Information Notice No. 81-26, PART 3, SUPPLEMENT NO. 1: CLARIFICATION OF
PLACEMENT OF PERSONNEL MONITORING DEVICES FOR EXTERNAL RADIATION
Addressees:
All nuclear power reactor facilities holding an operating license (OL) or
construction permit (CP), research and test reactors, fuel facilities, and
Priority I material licensees.
Purpose:
This information notice is a supplement to Information Notice No. 81-26, Part
3: Placement of Personnel Monitoring Devices for External Radiation
Exposure, issued in August 1981. Guidance provided in August 1981 concerning
dosimeter placement for determining whole body doses in situations where the
principal source of radiation is from underfoot was overly conservative.
Discussion:
The earlier guidance was,
"If the principal source of radiation is from underfoot, the
appropriate location for the dosimeter might be on the lower leg just
above the ankle, since the long bones of the lower leg contain active
blood-forming marrow."
As defined in 10 CFR 20.101(b)(3), "'dose to the whole body' shall be deemed
to include any dose to the whole body, gonads, active blood-forming organs,
head and trunk, or lens of eye."
According to the International Commission on Radiological Protection (ICRP)
publication No. 23, "Report of the Task Group on Reference Man," an adult's
long bones of the lower leg contain essentially no blood-forming red bone
marrow. Red marrow has been replaced by yellow marrow after the 18th year;
yellow marrow performs no blood-forming function and is mainly fatty tissue.
ICRP-23 shows for the reference man's femur (thigh bone) a steeply declining
red marrow content until the early to middle twenties when no red marrow is
evident in the femur shaft. However, in discussing red and yellow marrow
distributions, ICRP-23 states, "...it must be pointed out that there is much
variation, and exceptions should not be regarded as unusual." In the woman,
...the red marrow may occupy up to one-half to two-thirds of the shaft of
the femur. . . . "
Another factor is the body's ability to physically replace the yellow with
active, red marrow in periods of stress, such as anoxemia, blood loss,
anemia, etc. The time frame for the red for yellow marrow replacement was
not known when ICRP-23 was published.
8204210395
.
IN 81-26, Part 3, Sup. No. 1
July 19, 1982
Page 2 of 2
Guidance:
To monitor an adult for whole body doses when the principal source of
radiation is from underfoot, a reasonable placement for a whole body
dosimeter would be just above the knee. Any further generalization for whole
body dosimeter placement could be non-conservative, considering reported
variability because of age, race, sex, and state of general health. Note
that extremity monitoring requirements may dictate the placement of
additional dosimeters in the feet and ankle area.
No written response to this information is required. If you need additional
information regarding this matter, please contact the Regional Administrator
of the appropriate NRC Regional Office.
Edward L. Jordan, Director
Division of Engineering and
Quality Assurance
Technical Contact: J. E. Wigginton
301-492-4967
Attachment:
List of Recently Issued IE Information Notices