IE Circular No. 80-03, Protection from Toxic Gas Hazards
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 IE Circular No. 80-03 Date: March 6, 1980 PROTECTION FROM TOXIC GAS HAZARDS Chlorine gas releases have been reported at two different reactor facilities in the past two years. At Millstone, in March 1978, a leak of about 100 standard cubic feet of chlorine (about a gallon of liquid) occurred over a ten minute period. resulting in the hospitalization of 15 people. The ventilation system carried the chlorine into the plant buildings, where personnel distress was noted. No injuries occurred in the buildings due to the small size of the release. At Browns Ferry, in June 1979, a small leak from a diaphragm on a chlorine reducing valve resulted in the hospitalization of 5 people, including a control room operator. Chlorine is highly toxic, producing symptoms after several hours exposure in concentrations of only one ppm. Concentrations of 50 ppm are dangerous for even short exposures and 1000 ppm is fatal for brief exposures. Chlorine, used at some power stations to control organisms in the circulating water, is normally supplied in one ton containers or in tank cars of up to 90 tons capacity. Other potential sources of toxic gas that have been identified at nuclear power plants include: Nearby industrial facilities. At Waterford, in July 1979, construction forces had to be evacuated for two and a half hours due to a chlorine gas release from a nearby chemical plant. . Chlorine transportation on adjacent highways, railways and rivers. Large tanks of aqueous ammonia stored near plant buildings Both acid and caustic storage tanks located in a common building near the control room. At the Dresden site, in August 1977. accidental mixing of acid and caustic solutions resulted in toxic fumes that entered the control room via the ventilation system. Criterion 19 of Appendix A to 10 CFR 50 requires a control room for which action can be taken to maintain the reactor in a safe condition under accident conditions. The control room designs in current license applications are reviewed for operator protection from toxic gases (as well as radiation), in accordance with Standard Review Plan (SRP) 6.4 (NUREG 75/087 dated 11/24/75). Related information on the identification of potential hazards and the evaluation of potential accidents can be found in SRP sections 2.2.1-2.2.2 and 2.2.3, respectively. The SRP references Regulatory Guide 1.78 (dated June 1974) on control room habitability during chemical releases. It also references Regulatory Guide 1.95 on requirements for protection against chlorine releases specifically. The majority of the plants currently operating, however, were built and licensed prior to the development and implementation of this guidance. A review of some older plants, with respect to toxic gas hazards indicates that they do not have the degree of protection that would be required for present day plants. Evaluation of the protection of control rooms from toxic gas releases is part of the systematic evaluation program currently being carried out on certain older plants. Also, as older facilities submit requests for significant license amendments, their design features (continued next page) . and controls for protection of control rooms are reviewed and, if appropriate, are required to be changed. However, the recent history of frequent toxic gas release incidents appears to warrant a more rapid implementation of the newer toxic gas protection policies. For the above reasons, it is strongly recommended that: You evaluate your plant(s) against section 6.4 and applicable parts of sections 2.2.1-2.2.2 and 2.2.3 of the SRP with respect to toxic gas hazards. Where the degree of protection against toxic gas hazards is found to be significantly less than that specified in the SRP, provide the controls or propose the design changes necessary to achieve an equivalent level of protection. No written response to this circular is required. If you desire additional information regarding this matter, contact the Director of the appropriate NRC Regional Office. Enclosure: Sections 2.2.1-2.2.2 - 2.2.3 and 6.4 of NUREG 75/087
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021