Skip to main content

Power Reactor Status Report for March 22, 2026

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 100 *
Beaver Valley 2 100 *
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 91 Coastdown to Refueling Outage *
Hope Creek 1 100
Limerick 1 96 Coastdown to Refueling Outage *
Limerick 2 100
Millstone 2 100
Millstone 3 100
Nine Mile Point 1 100
Nine Mile Point 2 0 2026-03-09 Refueling outage
Peach Bottom 2 100
Peach Bottom 3 100
Salem 1 100
Salem 2 100
Seabrook 1 100 Contingency Down Power to < 1100MWe
Susquehanna 1 79 Coastdown to Refueling Outage; Maintain >300 MVAR *
Susquehanna 2 100

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 100
Browns Ferry 2 100
Browns Ferry 3 0 2026-02-21 Refueling Outage
Brunswick 1 0 2026-02-26 Refueling Outage *
Brunswick 2 100
Catawba 1 100
Catawba 2 100
Farley 1 100
Farley 2 100
Harris 1 100
Hatch 1 100
Hatch 2 100
McGuire 1 100
McGuire 2 0 2026-03-21 Refueling Outage *
North Anna 1 100 *
North Anna 2 100 *
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 100
Sequoyah 2 100
Summer 0 2026-02-28 Refueling Outage
Surry 1 100 *
Surry 2 100 *
Turkey Point 3 0 2026-02-04 Refueling Outage
Turkey Point 4 100
Vogtle 1 0 2026-02-22 Refueling outage
Vogtle 2 100
Vogtle 3 100
Vogtle 4 30 Reduced Power for Maintenance
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 0 2026-03-02 Refueling Outage
Byron 2 100
Clinton 100
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 0 2026-03-01 Refueling Outage
Dresden 2 100
Dresden 3 100
Fermi 2 91 Coastdown to Refueling Outage *
LaSalle 1 100
LaSalle 2 100
Monticello 0 2026-02-21 Maintenance Outage
Palisades 0 2025-09-09 Plant Restart
Perry 1 100
Point Beach 1 100
Point Beach 2 0 2026-03-14 Refueling Outage *
Prairie Island 1 100 *
Prairie Island 2 100 *
Quad Cities 1 100
Quad Cities 2 86 Coastdown to Refueling Outage

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 0 2026-03-14 Refueling Outage
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Grand Gulf 1 0 2026-02-14 Refueling Outage
Palo Verde 1 100
Palo Verde 2 0 2026-03-20 See EN58211; Refueling Outage *
Palo Verde 3 100
River Bend Station 1 100
South Texas 1 0 2026-03-20 Refueling Outage *
South Texas 2 100
Waterford 3 94 Transformer Limitation
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.