Skip to main content

Power Reactor Status Report for April 27, 2020

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 100 *
Beaver Valley 2 0 2020-04-11 REFUELING OUTAGE
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 0 2020-04-05 REFUELING OUTAGE *
Hope Creek 1 100
Indian Point 2 71 COASTDOWN TO DEFUELING *
Indian Point 3 100
Limerick 1 100
Limerick 2 100
Millstone 2 0 2020-04-23 REFUELING OUTAGE
Millstone 3 100
Nine Mile Point 1 100
Nine Mile Point 2 100
Peach Bottom 2 100
Peach Bottom 3 100
Salem 1 100
Salem 2 0 2020-04-10 REFUELING OUTAGE
Seabrook 1 0 2020-04-01 STARTUP IN PROGRESS *
Susquehanna 1 15 PLANT STARTUP IN PROGRESS HOLD FOR MAIN TURBINE/GENERATOR TROUBLESHOOTING *
Susquehanna 2 99 MAINTAIN 100 MVAR DUE TO GRID INSTABILITIES 100% ELECTRICAL CAPABILITY
Three Mile Island 1 0 2019-09-20 REACTOR DEFUELED FOR PERMANENT SHUTDOWN

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 100
Browns Ferry 2 100
Browns Ferry 3 100 *
Brunswick 1 100
Brunswick 2 100
Catawba 1 95 COASTDOWN TO REFUELING OUTAGE
Catawba 2 100
Farley 1 100
Farley 2 100
Harris 1 100
Hatch 1 100
Hatch 2 96 INCREASING POWER *
McGuire 1 100
McGuire 2 100
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 0 2020-04-10 REFUELING OUTAGE
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 100
Sequoyah 2 0 2020-04-10 REFUELING OUTAGE *
Summer 0 2020-04-10 REFUELING OUTAGE
Surry 1 100
Surry 2 85 COASTDOWN TO REFUELING OUTAGE
Turkey Point 3 71 INCREASING POWER PER POWER ASCENSION PLAN *
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 0 2020-04-19 REFUELING OUTAGE
Byron 1 100
Byron 2 100
Clinton 99 100% ELECTRICAL CAPABILITY *
D.C. Cook 1 100 *
D.C. Cook 2 100 *
Davis-Besse 100 *
Dresden 2 24 DOWNPOWER DUE TO TRIP OF RECIRC PUMP *
Dresden 3 100
Duane Arnold 100
Fermi 2 0 2020-03-21 REFUELING OUTAGE
LaSalle 1 100
LaSalle 2 100
Monticello 80 FLEXIBLE OPERATIONS *
Palisades 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 79 LOAD DISPATCHER REQUEST *
Quad Cities 1 100
Quad Cities 2 85 HOLDING POWER DOWNPOWER DUE TO FEEDWATER LEAK *

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100
Comanche Peak 2 0 2020-04-19 REFUELING OUTAGE
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Grand Gulf 1 0 2020-02-22 REFUELING OUTAGE
Palo Verde 1 100
Palo Verde 2 0 2020-04-03 REFUELING OUTAGE *
Palo Verde 3 100
River Bend Station 1 100
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.