Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for January 13, 2019

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100      
Beaver Valley 2 100      
Calvert Cliffs 1 100      
Calvert Cliffs 2 100      
FitzPatrick 100      
Ginna 100      
Hope Creek 1 100      
Indian Point 2 100      
Indian Point 3 100      
Limerick 1 100      
Limerick 2 99   REDUCED DUE TO ADMINISTRATIVE MOISTURE LIMIT *  
Millstone 2 100      
Millstone 3 100      
Nine Mile Point 1 100      
Nine Mile Point 2 100      
Oyster Creek 0 09/17/2018 PERMANENTLY SHUTDOWN    
Peach Bottom 2 100      
Peach Bottom 3 100      
Pilgrim 1 100      
Salem 1 100      
Salem 2 100      
Seabrook 1 100      
Susquehanna 1 100      
Susquehanna 2 99   COASTDOWN TO REFUELING OUTAGE *  
Three Mile Island 1 100      

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 96   HOLDING POWER FOR EPU TESTING    
Browns Ferry 2 100      
Browns Ferry 3 100      
Brunswick 1 100      
Brunswick 2 98   FLOW LIMITED *  
Catawba 1 100      
Catawba 2 100      
Farley 1 100      
Farley 2 100      
Harris 1 100      
Hatch 1 100      
Hatch 2 98   COASTDOWN TO REFUELING OUTAGE    
McGuire 1 100      
McGuire 2 100      
North Anna 1 100      
North Anna 2 100      
Oconee 1 100      
Oconee 2 100      
Oconee 3 100      
Robinson 2 100      
Saint Lucie 1 100      
Saint Lucie 2 100      
Sequoyah 1 100      
Sequoyah 2 100      
Summer 100      
Surry 1 100      
Surry 2 100      
Turkey Point 3 100      
Turkey Point 4 100      
Vogtle 1 100      
Vogtle 2 100      
Watts Bar 1 100      
Watts Bar 2 100      

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100      
Braidwood 2 100      
Byron 1 100      
Byron 2 100      
Clinton 98   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100      
D.C. Cook 2 100      
Davis-Besse 0 01/12/2019 MAINTENANCE OUTAGE *  
Dresden 2 100      
Dresden 3 100      
Duane Arnold 100      
Fermi 2 100      
LaSalle 1 100      
LaSalle 2 95   COASTDOWN TO REFUELING OUTAGE *  
Monticello 98   COASTDOWN TO REFUELING OUTAGE    
Palisades 100   *  
Perry 1 87   COASTDOWN TO REFUELING OUTAGE    
Point Beach 1 100      
Point Beach 2 100      
Prairie Island 1 100      
Prairie Island 2 100      
Quad Cities 1 100      
Quad Cities 2 100      

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100      
Arkansas Nuclear 2 100      
Callaway 100      
Columbia Generating Station 99   INCREASING POWER *  
Comanche Peak 1 100      
Comanche Peak 2 0 12/08/2018 REFUELING OUTAGE *  
Cooper 100      
Diablo Canyon 1 100      
Diablo Canyon 2 100      
Grand Gulf 1 100      
Palo Verde 1 100      
Palo Verde 2 100      
Palo Verde 3 100      
River Bend 1 70   REDUCED POWER FOR MAINTENANCE COASTDOWN TO REFUELING OUTAGE *  
South Texas 1 100      
South Texas 2 100      
Waterford 3 0 01/04/2019 REFUELING OUTAGE    
Wolf Creek 1 100      

Page Last Reviewed/Updated Thursday, March 25, 2021