Skip to main content

Power Reactor Status Report for September 27, 2018

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100      
Beaver Valley 2 93   COASTDOWN TO REFUELING OUTAGE *  
Calvert Cliffs 1 100      
Calvert Cliffs 2 100      
FitzPatrick 0 09/10/2018 REFUELING OUTAGE    
Ginna 100      
Hope Creek 1 100      
Indian Point 2 100      
Indian Point 3 100      
Limerick 1 100      
Limerick 2 100      
Millstone 2 90   COASTDOWN TO REFUELING OUTAGE    
Millstone 3 100      
Nine Mile Point 1 100      
Nine Mile Point 2 100      
Oyster Creek 0 09/17/2018 PERMANENTLY SHUTDOWN    
Peach Bottom 2 91   150 MVAR RESTRICTION FOR TURBINE VIBRATION COASTDOWN TO REFUELING OUTAGE    
Peach Bottom 3 92   INCREASING POWER PER POWER ASCENSION PLAN *  
Pilgrim 1 96   ROD PATTERN ADJUSTMENT *  
Salem 1 100      
Salem 2 67   HOLDING POWER DUE TO VIBRATION ISSUE    
Seabrook 1 95   COASTDOWN TO REFUELING OUTAGE *  
Susquehanna 1 100      
Susquehanna 2 100      
Three Mile Island 1 100      

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 79   REDUCED POWER DUE TO FEEDWATER HEATER TUBE LEAK    
Browns Ferry 2 100      
Browns Ferry 3 72   REDUCED POWER DUE TO FEEDWATER HEATER TUBE LEAK    
Brunswick 1 91   GRID GENERATION RESTRICTIONS IN EFFECT *  
Brunswick 2 94   GRID GENERATION RESTRICTIONS IN EFFECT    
Catawba 1 100      
Catawba 2 100      
Farley 1 0 09/24/2018 MAINTENANCE OUTAGE FOR AIRLEAK ON MSIV    
Farley 2 100      
Harris 1 100      
Hatch 1 100      
Hatch 2 100      
McGuire 1 100      
McGuire 2 0 09/14/2018 REFUELING OUTAGE    
North Anna 1 100      
North Anna 2 100      
Oconee 1 100      
Oconee 2 100      
Oconee 3 100      
Robinson 2 0 09/22/2018 REFUELING OUTAGE    
Saint Lucie 1 100      
Saint Lucie 2 0 08/26/2018 REFUELING OUTAGE    
Sequoyah 1 100      
Sequoyah 2 100      
Summer 100      
Surry 1 100      
Surry 2 100      
Turkey Point 3 100      
Turkey Point 4 100      
Vogtle 1 0 09/16/2018 REFUELING OUTAGE    
Vogtle 2 100      
Watts Bar 1 0 09/14/2018 REFUELING OUTAGE    
Watts Bar 2 100      

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100   *  
Braidwood 2 96   COASTDOWN TO REFUELING OUTAGE *  
Byron 1 49   INCREASING POWER FOLLOWING STARTUP *  
Byron 2 100      
Clinton 98   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100      
D.C. Cook 2 100      
Davis-Besse 100      
Dresden 2 100      
Dresden 3 92   COASTDOWN TO REFUELING OUTAGE    
Duane Arnold 100   *  
Fermi 2 0 09/21/2018 REFUELING OUTAGE    
LaSalle 1 100      
LaSalle 2 100      
Monticello 100      
Palisades 100      
Perry 1 100      
Point Beach 1 100      
Point Beach 2 94   COASTDOWN TO REFUELING OUTAGE    
Prairie Island 1 0 09/21/2018 REFUELING OUTAGE    
Prairie Island 2 100      
Quad Cities 1 0 09/26/2018 REACTOR SCRAM. SEE EN 53626. * 1
Quad Cities 2 100      

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100      
Arkansas Nuclear 2 0 09/16/2018 FORCED OUTAGE - MAIN FEED LEAK    
Callaway 100      
Columbia Generating Station 100      
Comanche Peak 1 100      
Comanche Peak 2 100      
Cooper 86   COASTDOWN TO REFUELING OUTAGE *  
Diablo Canyon 1 100      
Diablo Canyon 2 100      
Grand Gulf 1 95   XENON TRANSIENT *  
Palo Verde 1 100      
Palo Verde 2 96   COASTDOWN TO REFUELING OUTAGE *  
Palo Verde 3 100      
River Bend 1 99   *  
South Texas 1 96   COASTDOWN TO REFUELING OUTAGE *  
South Texas 2 100      
Waterford 3 100      
Wolf Creek 1 100      

Page Last Reviewed/Updated Thursday, August 27, 2026