Skip to main content

Power Reactor Status Report for March 19, 2018

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100     *  
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 0 03/18/2018 REFUELING OUTAGE *  
Indian Point 3 100   RESTRICTING 138KV FEEDERS 96951 AND 96952 WHILE 95891 OOS *  
Limerick 1 88   COASTDOWN TO REFUELING OUTAGE *  
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 0 03/17/2018 MAINTENANCE OUTAGE    
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100   150 MVAR RESTRICTION FOR TURBINE VIBRATION    
Peach Bottom 3 100        
Pilgrim 1 0 03/06/2018 MAINTENANCE OUTAGE SEE EN# 53259 OFFSITE POWER UNAVAILABLE    
Salem 1 100        
Salem 2 100        
Seabrook 1 100   ONE CONTINGENCY AWAY FROM DOWNPOWER (CONDITION WILL CONTINUE TO ~ MAY 1)    
Susquehanna 1 82   COASTDOWN TO REFUELING OUTAGE    
Susquehanna 2 100        
Three Mile Island 1 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/18/2018 PLANT SCRAM SEE EN #53269 *  
Browns Ferry 2 100        
Browns Ferry 3 0 02/16/2018 REFUELING OUTAGE    
Brunswick 1 0 03/03/2018 REFUELING OUTAGE    
Brunswick 2 100        
Catawba 1 100        
Catawba 2 0 03/16/2018 REFUELING OUTAGE *  
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 0 03/10/2018 REFUELING OUTAGE    
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 0 03/11/2018 REFUELING OUTAGE    
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        
Watts Bar 2 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 98   HOLDING POWER    
D.C. Cook 1 100        
D.C. Cook 2 0 02/28/2018 REFUELING OUTAGE    
Davis-Besse 0 03/02/2018 REFUELING OUTAGE    
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100     *  
Fermi 2 100        
LaSalle 1 100        
LaSalle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 0 03/19/2018 COASTDOWN TO REFUELING OUTAGE *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100     *  
Diablo Canyon 1 100        
Diablo Canyon 2 0 02/10/2018 REFUELING OUTAGE *  
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 90   POWER LIMITED TO 90% FOR CONDENSATE PUMP REPLACEMENT (~3/31/18) *  
South Texas 1 100     *  
South Texas 2 95   COASTDOWN TO REFUELING OUTAGE *  
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Thursday, August 27, 2026

Page Last Reviewed/Updated Thursday, August 27, 2026