Power Reactor Status Report for September 3, 2016

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 99   COASTDOWN TO REFUELING OUTAGE *  
Beaver Valley 2 100        
Calvert Cliffs 1 100   HIGH SYSTEM VOLTAGE ACTION *  
Calvert Cliffs 2 100   HIGH SYSTEM VOLTAGE ACTION *  
FitzPatrick 88   COASTDOWN TO REFUELING OUTAGE *  
Ginna 100        
Hope Creek 1 100   HIGH SYSTEM VOLTAGE ACTION *  
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 91   REDUCE POWER-TURBINE VALVE TESTING *  
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100   ONE OFFSITE SOURCE (115 KV) OUT OF SERVICE *  
Nine Mile Point 2 100        
Oyster Creek 100   COASTDOWN TO REFUELING OUTAGE *  
Peach Bottom 2 59   100 MVAR LIMIT FOR TURBINE BEARING VIBRATION COASTDOWN TO REFUELING OUTAGE REDUCE POWER-PLANT TESTING *  
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 60   DOWNPOWER DUE TO STEAM GENERATOR FEED PUMP ISSUES    
Salem 2 0 08/31/2016 TRIP DUE TO LOSS OF REACTOR COOLANT PUMP SEE EN #52213    
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100   HIGH SYSTEM VOLTAGE ACTION *  

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 89   COASTDOWN TO REFUELING OUTAGE *  
Browns Ferry 2 100        
Browns Ferry 3 65   REDUCED POWER FOR ROD PATTERN ADJUSTMENT *  
Brunswick 1 70   REDUCE POWER - ONE OFFSITE POWER SOURCE OUT OF SERVICE *  
Brunswick 2 100        
Catawba 1 100        
Catawba 2 97   COASTDOWN TO REFUELING OUTAGE    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 98   COASTDOWN TO REFUELING OUTAGE    
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 0 08/24/2016 FORCED OUTAGE    
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 12   PREPARE TO SYNCHRONIZE TO THE GRID INCREASING POWER *  
Watts Bar 2 0 08/30/2016 REACTOR TRIP DUE TO MAIN TRANSFORMER FIRE. SEE EN# 52210.    

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 80   REDUCED POWER FOR ROD PATTERN ADJUSTMENT *  
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 93   COASTDOWN TO REFUELING OUTAGE    
Duane Arnold 95   COASTDOWN TO REFUELING OUTAGE *  
Fermi 2 99   INCREASING POWER AFTER ROD PATTERN ADJUSTMENT *  
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 94   COASTDOWN TO REFUELING OUTAGE    
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 09/02/2016 SHUTDOWN DUE TO RCS LEAK, SEE EN 52218 *  