Power Reactor Status Report for July 26, 2016

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100     *  
Beaver Valley 2 100     *  
Calvert Cliffs 1 100   HOT WEATHER ALERT    
Calvert Cliffs 2 100   HOT WEATHER ALERT    
FitzPatrick 83   CONDENSATE BOOSTER PUMP MAINTENANCE    
Ginna 100        
Hope Creek 1 100   HOT WEATHER ALERT *  
Indian Point 2 100        
Indian Point 3 100   13.8 kV and 138 kV FEEDER RESTRICTIONS    
Limerick 1 100     *  
Limerick 2 100     *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100   100 MVAR LIMIT FOR TURBINE BEARING VIBRATION *  
Peach Bottom 3 100     *  
Pilgrim 1 100        
Salem 1 0 04/14/2016 REFUELING OUTAGE HEAT UP IN PROGRESS    
Salem 2 14   GENERATOR OFF-LINE DUE TO GENERATOR GROUNDS HOLDING POWER    
Seabrook 1 100        
Susquehanna 1 100   HOT WEATHER ALERT    
Susquehanna 2 100   HOT WEATHER ALERT    
Three Mile Island 1 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 37   REDUCED POWER FOR PLANNED MAINTENANCE *  
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Farley 1 100     *  
Farley 2 100     *  
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 100   HOT WEATHER ALERT    
North Anna 2 100   HOT WEATHER ALERT    
Oconee 1 100   HOT WEATHER ALERT *  
Oconee 2 100   HOT WEATHER ALERT *  
Oconee 3 100   HOT WEATHER ALERT *  
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 93   FEEDWATER BOOSTER PUMP TRIP *  
Surry 1 100   HOT WEATHER ALERT    
Surry 2 100   HOT WEATHER ALERT    
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 90   CONDENSER BACK PRESSURE ISSUES *  
Watts Bar 2 74   POWER ASCENSION TESTING INCREASING POWER *  

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100     *  
Byron 2 100     *  
Clinton 99   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100   HOT WEATHER ALERT *  
D.C. Cook 2 78   DOWNPOWER DUE TO OFFSITE POWER LINE ISSUE HOT WEATHER ALERT *  
Davis-Besse 100     *  
Dresden 2 100     *  
Dresden 3 100     *  
Duane Arnold 98   ROD SOAK AFTER PATTERN ADJUSTMENT    
Fermi 2 100        
La Salle 1 100     *  
La Salle 2 100     *  
Monticello 100        
Palisades 100        
Perry 1 98   REDUCED POWER DUE TO AMBIENT CONDITIONS INCREASING POWER *  
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100     *  
Quad Cities 2 100     *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 97   INCREASING POWER AFTER ROD PATTERN ADJUSTMENT *  
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Thursday, March 25, 2021