Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for July 22, 2016

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100   HOT WEATHER ALERT *  
Beaver Valley 2 100   HOT WEATHER ALERT *  
Calvert Cliffs 1 100   HOT WEATHER ALERT *  
Calvert Cliffs 2 100   HOT WEATHER ALERT *  
FitzPatrick 83   CONDENSATE BOOSTER PUMP MAINTENANCE *  
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100   13.8 kV and 138 kV FEEDER RESTRICTIONS    
Limerick 1 100   HOT WEATHER ALERT *  
Limerick 2 100   HOT WEATHER ALERT *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100   100 MVAR LIMIT FOR TURBINE BEARING VIBRATION    
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 0 04/14/2016 REFUELING OUTAGE    
Salem 2 28     *  
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 98   POWER SUPPLY ALERT DUE TO HIGH AMBIENT TEMP AND GRID LOADING COASTDOWN TO REFUELING OUTAGE *  
Browns Ferry 2 100   POWER SUPPLY ALERT DUE TO HIGH AMBIENT TEMP AND GRID LOADING    
Browns Ferry 3 100   POWER SUPPLY ALERT DUE TO HIGH AMBIENT TEMP AND GRID LOADING    
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Farley 1 100   CONSERVATIVE OPERATIONS WATCH *  
Farley 2 100   CONSERVATIVE OPERATIONS WATCH *  
Harris 1 100        
Hatch 1 100   CONSERVATIVE OPERATIONS WATCH    
Hatch 2 100   CONSERVATIVE OPERATIONS WATCH    
McGuire 1 100        
McGuire 2 100        
North Anna 1 100   HOT WEATHER ALERT *  
North Anna 2 100   HOT WEATHER ALERT *  
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100   POWER SUPPLY ALERT    
Sequoyah 2 100   POWER SUPPLY ALERT    
Summer 100        
Surry 1 100   HOT WEATHER ALERT *  
Surry 2 100   HOT WEATHER ALERT *  
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 94   CONDENSER BACK PRESSURE ISSUES POWER SUPPLY ALERT *  
Watts Bar 2 46   POWER SUPPLY ALERT *  

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100   HOT WEATHER ALERT *  
Byron 2 100   HOT WEATHER ALERT *  
Clinton 99   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 75   DOWNPOWER DUE TO OFFSITE POWER LINE ISSUE *  
Davis-Besse 100   HOT WEATHER ALERT *  
Dresden 2 100   HOT WEATHER ALERT    
Dresden 3 100   HOT WEATHER ALERT    
Duane Arnold 99   ROD SOAK AFTER PATTERN ADJUSTMENT    
Fermi 2 100   HOT WEATHER ALERT *  
La Salle 1 100   HOT WEATHER ALERT    
La Salle 2 100   HOT WEATHER ALERT    
Monticello 100     *  
Palisades 100        
Perry 1 96   DOWNPOWER DUE TO CIRCULATING WATER TEMPERATURE LIMITS *  
Point Beach 1 100   HOT WEATHER ALERT *  
Point Beach 2 100   HOT WEATHER ALERT *  
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100   HOT WEATHER ALERT    
Quad Cities 2 100   HOT WEATHER ALERT    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 84   INCREASING POWER *  
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 37   INCREASING POWER *  
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021