Power Reactor Status Report for June 4, 2016

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 80   REDUCED POWER FOR CONDENSER TUBE LEAK SEARCH AND REPAIR *  
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 95   INCREASING POWER TO 100% *  
Ginna 100        
Hope Creek 1 60   REDUCED POWER FOR TURBINE VALVE TESTING AND WATERBOX CLEANING *  
Indian Point 2 0 03/07/2016 REFUELING OUTAGE - CORE RELOAD COMPLETE *  
Indian Point 3 100   MAINTENANCE AFFECTING 138KV FEEDERS 95331, 95332, 13W92, AND 13W93 TO WORK ON BT 4-5 - 345KV RING FEEDER HOTSPOT - RESTRICTED FEEDERS W97 AND Y88 *  
Limerick 1 100        
Limerick 2 100     *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100   100 MVAR RESTRICTION DUE TO TURBINE BEARING VIBRATIONS    
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 0 04/14/2016 REFUELING OUTAGE    
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 59   REDUCED POWER FOR ROD PATTERN ADJUSTMENT AND SCHEDULED RPS TESTING *  
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Farley 1 92   INCREASING POWER TO 100% *  
Farley 2 100        
Harris 1 100        
Hatch 1 96   REDUCED POWER FOR TURBINE TESTING *  
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 97   INCREASING POWER TO 100% *  
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        
Watts Bar 2 18   HOLDING FOR TURBINE TESTING AND REPAIR OF SMALL SECONDARY STEAM LEAK *  

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY *  
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100        
Fermi 2 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100     *  
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 48   HOLDING POWER FOR FLUX MAP *  
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 98   HOLDING POWER FOR FEED REGULATING VALVE ISSUE. *  
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        