The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Power Reactor Status Report for April 27, 2014

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 0 04/18/2014 REFUELING OUTAGE    
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100     *  
Ginna 99   COASTDOWN TO REFUELING OUTAGE - WILL SHUTDOWN TOMORROW FOR REFUELING OUTAGE *  
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100     *  
Limerick 2 0 04/24/2014 MAINTENANCE OUTAGE - TURBINE BLADE REPLACEMENT    
Millstone 2 0 04/05/2014 DEFUELED    
Millstone 3 100        
Nine Mile Point 1 98   INCREASING POWER TO 100% *  
Nine Mile Point 2 0 03/23/2014 REFUELING OUTAGE    
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 04/12/2014 DEFUELED    
Seabrook 1 86   INCREASING POWER TO 94% FOR 5 HOUR FUEL CONDITIONING HOLD - SINGLE DOWNPOWER CONTINGENCY IN EFFECT DUE TO PLANNED LINE MAINTENANCE *  
Susquehanna 1 0 04/12/2014 REFUELING OUTAGE    
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 81   INCREASING POWER TO 100% *  
Catawba 1 100        
Catawba 2 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 99   INCREASING POWER TO 100% *  
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 0 04/14/2014 DEFUELED    
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 86   COASTDOWN TO REFUELING OUTAGE    
Summer 0 04/04/2014 DEFUELED    
Surry 1 100        
Surry 2 0 04/20/2014 REFUELING OUTAGE    
Turkey Point 3 47   HOLDING POWER FOR NI GAIN ADJUST PRIOR TO FLUX MAPPING *  
Turkey Point 4 100        
Vogtle 1 99   INCREASING POWER TO 100% *  
Vogtle 2 100        
Watts Bar 1 0 03/23/2014 REFUELING OUTAGE *  

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 98   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 0 01/31/2014 REFUELING OUTAGE    
Dresden 2 17   STEAM CHEST WARMING *  
Dresden 3 100        
Duane Arnold 100        
Fermi 2 93   HOLDING POWER FOR PLANT TESTING *  
La Salle 1 100        
La Salle 2 2   SHUTTING DOWN FOR PLANNED MAINTENANCE OUTAGE *  
Monticello 88   ENGINEERING HOLD FOR EPU TESTING    
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 42   REDUCED POWER FOR SCHEDULED CONDENSER CLEANING    
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 0 03/31/2014 REFUELING OUTAGE    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 95   COASTDOWN TO REFUELING OUTAGE *  
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 1   CRITICAL IN INTERMEDIATE RANGE - PHYSICS TESTING *  
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100     *  
Grand Gulf 1 86   HOLDING POWER DUE TO HEATER DRAIN PUMP VIBRATION    
Palo Verde 1 100        
Palo Verde 2 0 04/04/2014 REFUELING OUTAGE    
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 0 03/15/2014 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 0 04/12/2014 DEFUELED    
Wolf Creek 1 0 03/07/2014 MID CYCLE PLANNED MAINTENANCE OUTAGE - RCS LOOPS FILLED    

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Thursday, March 25, 2021