Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for March 27, 2014

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100   95331 FEEDER OOS FOR MAINTENANCE    
Indian Point 3 100   95331 FEEDER OOS FOR MAINTENANCE    
Limerick 1 0 03/04/2014 REFUELING OUTAGE    
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 0 03/23/2014 REFUELING OUTAGE    
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100   JUMPERS INSTALLED AROUND MAIN GENERATOR DISCONNECT    
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 74   INCREASING POWER *  
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 78   DECREASED POWER FOR FEEDWATER HEATER MAINTENANCE    
Browns Ferry 2 100        
Browns Ferry 3 98   INCREASING POWER *  
Brunswick 1 0 02/28/2014 REFUELING OUTAGE    
Brunswick 2 100        
Catawba 1 100     *  
Catawba 2 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/21/2014 REFUELING OUTAGE    
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 0 03/07/2014 FORCED OUTAGE - SHUTDOWN FOR SG TUBE REPAIRS - DEFUELED    
Saint Lucie 1 100        
Saint Lucie 2 0 03/02/2014 REFUELING OUTAGE    
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 0 03/16/2014 REFUELING OUTAGE    
Turkey Point 4 100        
Vogtle 1 0 03/16/2014 REFUELING OUTAGE    
Vogtle 2 100        
Watts Bar 1 0 03/23/2014 REFUELING OUTAGE    

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 0 03/09/2014 REFUELING OUTAGE *  
Byron 2 100        
Clinton 3   INCREASING POWER *  
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 0 01/31/2014 REFUELING OUTAGE    
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100        
Fermi 2 0 02/10/2014 REFUELING OUTAGE    
La Salle 1 100        
La Salle 2 100        
Monticello 88   ENGINEERING HOLD FOR EPU TESTING    
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 0 03/16/2014 REFUELING OUTAGE    
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 88   COASTDOWN TO REFUELING OUTAGE    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 3   INCREASING POWER *  
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 80   INCREASING POWER *  
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 0 03/15/2014 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 03/07/2014 MID CYCLE PLANNED MAINTENANCE OUTAGE    

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021