Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for November 13, 2013

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 70   INCREASING POWER *  
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100     *  
Indian Point 2 100   13.8 KV LINE 33332LM OOS    
Indian Point 3 100   13.8 KV LINE 33332LM OOS    
Limerick 1 100        
Limerick 2 100        
Millstone 2 80   INCREASING POWER *  
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100   345 KV LINE 342 OUT OF SERVICE    
Salem 1 100        
Salem 2 100        
Seabrook 1 100   ONE CONTINGENCY AWAY FROM DOWN POWER TO 800MW DUE TO LINE OUTAGE UNTIL 11/17/13 *  
Susquehanna 1 98   LIMITED BY GENERATOR CURVE *  
Susquehanna 2 99   LIMITED BY GENERATOR CURVE *  
Three Mile Island 1 0 10/27/2013 REFUELING OUTAGE    
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Farley 1 100        
Farley 2 100        
Harris 1 0 11/08/2013 REFUELING OUTAGE - RCS DEPRESSURIZED    
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 98   FORMER 100% NOW 98% BECAUSE OF POWER UPRATE    
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 11/11/2013 FORCED OUTAGE TS REQUIRED SHUTDOWN DUE TO RCS PRESSURE BOUNDARY LEAKAGE SEE EN # 49527    
Oconee 2 0 10/11/2013 REFUELING OUTAGE    
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 6   INCREASING POWER *  
Saint Lucie 2 100        
Sequoyah 1 0 10/14/2013 REFUELING OUTAGE    
Sequoyah 2 100        
Summer 100        
Surry 1 0 10/19/2013 REFUELING OUTAGE    
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 46   HOLDING FOR NI CALIBRATION *  
Davis-Besse 100        
Dresden 2 0 11/10/2013 REFUELING OUTAGE *  
Dresden 3 100        
Duane Arnold 98   REDUCED POWER PER LOAD DISPATCHER INSTRUCTIONS    
Fermi 2 100     *  
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 0 09/21/2013 REFUELING OUTAGE    
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 99        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 MAINTENANCE OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 0 10/04/2013 REFUELING OUTAGE    
River Bend 1 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021