Power Reactor Status Report for June 1, 2013
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Beaver Valley 1 | 100 | ||||
Beaver Valley 2 | 0 | 05/27/2013 | FORCED OUTAGE | ||
Calvert Cliffs 1 | 100 | HOT WEATHER ALERT | |||
Calvert Cliffs 2 | 100 | HOT WEATHER ALERT | |||
FitzPatrick | 100 | ||||
Ginna | 100 | ||||
Hope Creek 1 | 100 | ||||
Indian Point 2 | 100 | 13.8 KV LINE 33332LM OOS | |||
Indian Point 3 | 100 | 13.8 KV LINE 33332LM OOS | |||
Limerick 1 | 100 | ||||
Limerick 2 | 100 | ||||
Millstone 2 | 100 | ||||
Millstone 3 | 100 | ||||
Nine Mile Point 1 | 100 | ||||
Nine Mile Point 2 | 100 | * | |||
Oyster Creek | 70 | TROUBLESHOOTING FEED WATER REG VALVE | * | ||
Peach Bottom 2 | 100 | ||||
Peach Bottom 3 | 100 | ||||
Pilgrim 1 | 50 | HOLDING FOR CONDENSER VACUUM PROBLEMS | * | ||
Salem 1 | 98 | HOLDING FOR TESTING | |||
Salem 2 | 100 | ||||
Seabrook 1 | 100 | ||||
Susquehanna 1 | 0 | 05/08/2013 | MAINTENANCE OUTAGE | ||
Susquehanna 2 | 15 | NOT SYNCED TO THE GRID; HOT WEATHER ALERT | * | ||
Three Mile Island 1 | 100 | HOT WEATHER ALERT | |||
Vermont Yankee | 99 | DECREASED POWER TO CHLORINATE CIRC WATER | * |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Browns Ferry 1 | 100 | ||||
Browns Ferry 2 | 100 | ||||
Browns Ferry 3 | 88 | ROD SEQUENCE EXCHANGE | * | ||
Brunswick 1 | 95 | INCREASING POWER | * | ||
Brunswick 2 | 100 | ||||
Catawba 1 | 48 | MAINTENANCE ON 1B FEEDWATER PUMP | * | ||
Catawba 2 | 100 | ||||
Crystal River 3 | 0 | 02/03/2013 | PERMANENT PLANT SHUTDOWN | ||
Farley 1 | 100 | ||||
Farley 2 | 100 | ||||
Harris 1 | 0 | 05/15/2013 | FORCED OUTAGE | ||
Hatch 1 | 61 | DECREASED POWER TO FIND FUEL LEAK | * | ||
Hatch 2 | 100 | ||||
McGuire 1 | 100 | ||||
McGuire 2 | 100 | ||||
North Anna 1 | 100 | HOT WEATHER ALERT | |||
North Anna 2 | 99 | HOT WEATHER ALERT INCREASING POWER | * | ||
Oconee 1 | 100 | ||||
Oconee 2 | 100 | ||||
Oconee 3 | 100 | ||||
Robinson 2 | 100 | ||||
Saint Lucie 1 | 100 | ||||
Saint Lucie 2 | 0 | 05/31/2013 | FORCED OUTAGE SEE EN #49082 | * | 1 |
Sequoyah 1 | 100 | GRID STATUS YELLOW DUE TO WIDOW CREEK 500 kV LINE OOS | |||
Sequoyah 2 | 100 | GRID STATUS YELLOW DUE TO WIDOW CREEK 500 kV LINE OOS | |||
Summer | 100 | ||||
Surry 1 | 100 | HOT WEATHER ALERT | |||
Surry 2 | 100 | HOT WEATHER ALERT | |||
Turkey Point 3 | 100 | ||||
Turkey Point 4 | 100 | * | |||
Vogtle 1 | 100 | ||||
Vogtle 2 | 16 | ENTERING OUTAGE TO REPLACE RCP SEALS | * | ||
Watts Bar 1 | 100 |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Braidwood 1 | 100 | ||||
Braidwood 2 | 100 | ||||
Byron 1 | 100 | ||||
Byron 2 | 100 | ||||
Clinton | 97 | 100% ELECTRICAL CAPABILITY | |||
D.C. Cook 1 | 100 | ||||
D.C. Cook 2 | 100 | ||||
Davis-Besse | 100 | * | |||
Dresden 2 | 100 | ||||
Dresden 3 | 100 | ||||
Duane Arnold | 70 | ROD SEQUENCE EXCHANGE | * | ||
Fermi 2 | 68 | HOLDING - RX FEEDPUMP ISSUES | |||
Kewaunee | 0 | 05/07/2013 | PERMANENT PLANT SHUTDOWN | ||
La Salle 1 | 100 | ||||
La Salle 2 | 100 | ||||
Monticello | 0 | 03/01/2013 | REFUELING OUTAGE | ||
Palisades | 0 | 05/05/2013 | FORCED OUTAGE - TECH SPEC REQUIRED SHUTDOWN; SEE EN #49002 | ||
Perry 1 | 100 | ||||
Point Beach 1 | 100 | ||||
Point Beach 2 | 100 | ||||
Prairie Island 1 | 100 | ||||
Prairie Island 2 | 100 | ||||
Quad Cities 1 | 100 | * | |||
Quad Cities 2 | 100 |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Arkansas Nuclear 1 | 0 | 03/24/2013 | REFUELING OUTAGE | ||
Arkansas Nuclear 2 | 100 | ||||
Callaway | 99 | INSTRUMENT CALIBRATION | * | ||
Columbia Generating Station | 0 | 05/11/2013 | REFUELING OUTAGE | ||
Comanche Peak 1 | 100 | ||||
Comanche Peak 2 | 100 | ||||
Cooper | 100 | ||||
Diablo Canyon 1 | 100 | ||||
Diablo Canyon 2 | 100 | ||||
Fort Calhoun | 0 | 04/09/2011 | REFUELING OUTAGE | ||
Grand Gulf 1 | 100 | ||||
Palo Verde 1 | 100 | ||||
Palo Verde 2 | 100 | ||||
Palo Verde 3 | 100 | ||||
River Bend 1 | 100 | ||||
San Onofre 2 | 0 | 01/09/2012 | REFUELING OUTAGE | ||
San Onofre 3 | 0 | 01/31/2012 | FORCED OUTAGE - S/G REPAIR | ||
South Texas 1 | 100 | ||||
South Texas 2 | 95 | SURVEILLANCE | * | ||
Waterford 3 | 100 | ||||
Wolf Creek 1 | 100 |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021