Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100   MINIMUM GENERATION ALERT *  
Beaver Valley 2 97   COASTDOWN TO REFUELING OUTAGE MINIMUM GENERATION ALERT    
Calvert Cliffs 1 100   MINIMUM GENERATION ALERT *  
Calvert Cliffs 2 100   MINIMUM GENERATION ALERT *  
FitzPatrick 91   COASTDOWN TO REFUELING OUTAGE *  
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100   138 KV FEEDER RESTRICTIONS    
Indian Point 3 100   138 KV FEEDER RESTRICTIONS    
Limerick 1 100        
Limerick 2 100        
Millstone 2 85   HTR DRAIN PUMP OOS *  
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 0 09/09/2012 REFUELING OUTAGE *  
Peach Bottom 3 100        
Pilgrim 1 100   MINIMUM GENERATION ALERT *  
Salem 1 100        
Salem 2 100        
Seabrook 1 85   POWER LIMITED TO 85% BASED ON GENERATOR STATOR COOLING DELTA T LIMIT    
Susquehanna 1 100   MINIMUM GENERATION ALERT    
Susquehanna 2 100   MINIMUM GENERATION ALERT    
Three Mile Island 1 100   MINIMUM GENERATION ALERT    
Vermont Yankee 100        

Region 2

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 09/25/2009 DEFUELED - CONTAINMENT TENSIONING ON HOLD    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 98   COASTDOWN TO REFUELING OUTAGE    
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 84   CIRCULATING WATER PUMP OOS    
Saint Lucie 2 0 08/05/2012 DEFUELED    
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 21   INCREASING POWER 30% PWR HOLD FOR SECONDARY CHEMISTRY *  
Turkey Point 4 100        
Vogtle 1 96   COASTDOWN TO REFUELING OUTAGE    
Vogtle 2 100        
Watts Bar 1 0 09/10/2012 REFUELING OUTAGE *  

Region 3

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100     *  
Braidwood 2 100     *  
Byron 1 0 09/10/2012 REFUELING OUTAGE *  
Byron 2 100     *  
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100   MINIMUM GENERATION ALERT *  
D.C. Cook 2 100   MINIMUM GENERATION ALERT *  
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 94   COASTDOWN TO REFUELING OUTAGE *  
Fermi 2 68   SOUTH FEED PUMP UNAVAILABLE    
Kewaunee 100   MIN GEN ALERT    
La Salle 1 100     *  
La Salle 2 100     *  
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100     *  
Quad Cities 2 100     *  

Region 4

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 93   COASTDOWN TO REFUELING OUTAGE    
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 REFUELING OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 0 01/09/2012 REFUELING OUTAGE    
San Onofre 3 0 01/31/2012 FORCED OUTAGE - S/G REPAIR    
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
Page Last Reviewed/Updated Tuesday, October 09, 2012