The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Power Reactor Status Report for March 27, 2012
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 98 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Beaver Valley 2 | 100 | * | |||
| Calvert Cliffs 1 | 0 | 02/05/2012 | REFUELING OUTAGE | * | |
| Calvert Cliffs 2 | 100 | * | |||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Indian Point 2 | 0 | 03/04/2012 | REFUELING OUTAGE | * | |
| Indian Point 3 | 100 | ||||
| Limerick 1 | 100 | * | |||
| Limerick 2 | 100 | ||||
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 98 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 100 | * | |||
| Salem 2 | 0 | 03/23/2012 | PLANT STARTUP IN PROGRESS - REACTOR IS CRITICAL | * | |
| Seabrook 1 | 85 | HOLDING POWER BASED ON GENERATOR STATOR COOLING DELTA T LIMIT. OFFSITE PWR LINE #3135 (369 KV) OOS | |||
| Susquehanna 1 | 98 | COASTDOWN TO REFUELING OUTAGE. | * | ||
| Susquehanna 2 | 99 | 100% ELECTRICAL CAPABILITY | * | ||
| Three Mile Island 1 | 100 | * | |||
| Vermont Yankee | 31 | REDUCED POWER FOR PLANNED MAINTENANCE ON A CONDENSER WATERBOX | * |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ||||
| Browns Ferry 2 | 100 | ||||
| Browns Ferry 3 | 97 | COASTDOWN TO REFUELING OUTAGE | |||
| Brunswick 1 | 0 | 02/23/2012 | REFUELING OUTAGE | ||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | ||||
| Catawba 2 | 0 | 03/10/2012 | DEFUELED | ||
| Crystal River 3 | 0 | 09/25/2009 | DEFUELED - CONTAINMENT TENSIONING ON HOLD | ||
| Farley 1 | 83 | COASTDOWN TO REFUELING OUTAGE | |||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 98 | HOLDING POWER FOR FUEL CONDITIONING | * | ||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 100 | ||||
| North Anna 1 | 0 | 03/10/2012 | REFUELING OUTAGE | ||
| North Anna 2 | 100 | ||||
| Oconee 1 | 100 | ||||
| Oconee 2 | 100 | ||||
| Oconee 3 | 94 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Robinson 2 | 55 | REDUCED TO REPAIR CONDENSER TUBE LEAK | * | ||
| Saint Lucie 1 | 0 | 11/27/2011 | HOLDING FOR RESTART | ||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 0 | 02/26/2012 | REFUELING OUTAGE | ||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 0 | 02/26/2012 | DEFUELED | ||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | FEEDFLOW INSTRUMENT LIMITED | |||
| Byron 2 | 100 | FEED WATER FLOW INVESTIGATION | |||
| Clinton | 97 | 100% ELECTRICAL CAPABILITY | |||
| D.C. Cook 1 | 100 | * | |||
| D.C. Cook 2 | 0 | 03/21/2012 | REFUELING OUTAGE | * | |
| Davis-Besse | 100 | ||||
| Dresden 2 | 100 | ||||
| Dresden 3 | 100 | ||||
| Duane Arnold | 100 | ||||
| Fermi 2 | 0 | 03/25/2012 | REFUELING OUTAGE | * | |
| Kewaunee | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 0 | 02/21/2012 | DEFUELED | ||
| Quad Cities 1 | 90 | HOLDING POWER DUE TO TURBINE VIBRATION | |||
| Quad Cities 2 | 0 | REFUELING OUTAGE |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 99 | HEATER DRAIN VALVE FAILURE | * | ||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | MORRO BAY MIDWAY #1 230 KV LINE OOS FOR MAINTENANCE | * | ||
| Diablo Canyon 2 | 100 | MORRO BAY MIDWAY #1 230 KV LINE OOS FOR MAINTENANCE | * | ||
| Fort Calhoun | 0 | 04/09/2011 | REFUELING OUTAGE | ||
| Grand Gulf 1 | 0 | 02/19/2012 | REFUELING OUTAGE | ||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 0 | 03/16/2012 | DEFUELED | * | |
| River Bend 1 | 100 | ||||
| San Onofre 2 | 0 | 01/09/2012 | REFUELING OUTAGE | ||
| San Onofre 3 | 0 | 01/31/2012 | FORCED OUTAGE | ||
| South Texas 1 | 100 | ||||
| South Texas 2 | 0 | 11/28/2011 | MAINTENANCE OUTAGE | ||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 9 | HOLDING FOR GRID SYNCH | * |
Page Last Reviewed/Updated Tuesday, August 25, 2026