Skip to main content

Power Reactor Status Report for November 10, 2009

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 0 10/11/2009 REFUELING OUTAGE    
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 10/06/2009 REFUELING OUTAGE    
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100     *  
Peach Bottom 3 100     *  
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 10/13/2009 REFUELING OUTAGE    
Seabrook 1 20   TURBINE OVERSPEED TESTING *  
Susquehanna 1 94   100% ELECTRICAL CAPABILITY    
Susquehanna 2 94   100% ELECTRICAL CAPABILITY    
Three Mile Island 1 0 10/25/2009 DEFUELED    
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100     *  
Browns Ferry 2 100     *  
Browns Ferry 3 100     *  
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 0 11/06/2009 REFUELING OUTAGE *  
Catawba 2 100     *  
Crystal River 3 0 09/25/2009 DEFUELED    
Farley 1 100   500KV RACCOON CREEK LINE OOS    
Farley 2 100   500KV RACCOON CREEK LINE OOS *  
Harris 1 100        
Hatch 1 100        
Hatch 2 63   REDUCED POWER TO PERFORM FLUX TILT TESTING TO IDENTIFY CONTROL ROD LEAK *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 10/09/2009 REFUELING OUTAGE    
Oconee 2 100        
Oconee 3 100        
Robinson 2 100     *  
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 0 10/25/2009 REFUELING OUTAGE - CORE RELOAD IN PROGRESS    
Summer 0 10/16/2009 DEFUELED    
Surry 1 100        
Surry 2 0 10/31/2009 DEFUELED    
Turkey Point 3 100        
Turkey Point 4 0 10/25/2009 DEFUELED    
Vogtle 1 100        
Vogtle 2 94   REDUCED POWER FOR PLANNED MAINTENANCE ON THE 2B HEATER DRAIN PUMP    
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 0 09/20/2008 FORCED OUTAGE - CORRECTED OUTAGE DATE    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 0 11/01/2009 REFUELING OUTAGE    
Dresden 3 95   INCREASING POWER *  
Duane Arnold 100        
Fermi 2 0 09/30/2009 FORCED OUTAGE    
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 0 10/14/2009 REFUELING OUTAGE    
Prairie Island 1 0 09/11/2009 REFUELING OUTAGE    
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 0 11/07/2009 SCRAM. SEE EN #45484.    
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 53   INCREASING POWER *  
Diablo Canyon 1 100        
Diablo Canyon 2 0 10/03/2009 REFUELING OUTAGE    
Fort Calhoun 0 10/31/2009 REFUELING OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 0 10/02/2009 DEFUELED    
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 0 09/26/2009 DEFUELED    
San Onofre 3 100        
South Texas 1 0 09/30/2009 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 0 10/19/2009 DEFUELED    
Wolf Creek 1 0 10/09/2009 REFUELING OUTAGE    

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021