Skip to main content

Power Reactor Status Report for November 8, 2009

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 0 10/11/2009 REFUELING OUTAGE *  
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100     *  
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 10/06/2009 REFUELING OUTAGE *  
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100   343 LINE OOS *  
Peach Bottom 3 100   343 LINE OOS *  
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 10/13/2009 REFUELING OUTAGE *  
Seabrook 1 0 09/30/2009 REFUELING OUTAGE *  
Susquehanna 1 87   ROD SEQUENCE EXCHANGE *  
Susquehanna 2 94   100% ELECTRICAL CAPABILITY    
Three Mile Island 1 0 10/25/2009 DEFUELED    
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 0 11/06/2009 REFUELING OUTAGE    
Catawba 2 98        
Crystal River 3 0 09/25/2009 DEFUELED    
Farley 1 100   500KV RACCOON CREEK LINE OOS    
Farley 2 0 11/05/2009 FORCED OUTAGE - SHUTDOWN TO REPAIR OIL LEAK ON PHASE 2 MAIN TRANSFORMER - 500KV RACCOON CREEK LINE OOS    
Harris 1 100        
Hatch 1 100        
Hatch 2 60   REDUCED POWER TO PERFORM FLUX TILT TESTING TO IDENTIFY CONTROL ROD LEAK *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 10/09/2009 REFUELING OUTAGE    
Oconee 2 100        
Oconee 3 100        
Robinson 2 0 11/06/2009 MANUAL REACTOR TRIP. SEE EN# 45483.    
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 0 10/25/2009 REFUELING OUTAGE *  
Summer 0 10/16/2009 DEFUELED    
Surry 1 100        
Surry 2 0 10/31/2009 REFUELING OUTAGE    
Turkey Point 3 100        
Turkey Point 4 0 10/25/2009 DEFUELED    
Vogtle 1 100        
Vogtle 2 94   REDUCED POWER FOR PLANNED MAINTENANCE ON THE 2B HEATER DRAIN PUMP    
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100     *  
Byron 1 100        
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY *  
D.C. Cook 1 0 09/20/2008 FORCED OUTAGE - CORRECTED OUTAGE DATE    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 0 11/01/2009 REFUELING OUTAGE - CORE SHUFFLE IN PROGRESS    
Dresden 3 17   OFFLINE FOR HYDRAULIC FLUID LEAK ON TURBINE STEAM STOP VALVE #4 *  
Duane Arnold 100        
Fermi 2 0 09/30/2009 FORCED OUTAGE    
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 0 10/14/2009 REFUELING OUTAGE    
Prairie Island 1 0 09/11/2009 REFUELING OUTAGE *  
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 0 11/07/2009 SCRAM. SEE EN #45484. * 1
Comanche Peak 1 100     *  
Comanche Peak 2 100        
Cooper 0 11/06/2009 MANUAL REACTOR SCRAM. SEE EN# 45482 *  
Diablo Canyon 1 100        
Diablo Canyon 2 0 10/03/2009 REFUELING OUTAGE    
Fort Calhoun 0 10/31/2009 REFUELING OUTAGE    
Grand Gulf 1 100     *  
Palo Verde 1 100        
Palo Verde 2 0 10/02/2009 DEFUELED    
Palo Verde 3 100        
River Bend 1 93   ROD ADJUSTMENTS *  
San Onofre 2 0 09/26/2009 DEFUELED    
San Onofre 3 100        
South Texas 1 0 09/30/2009 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 0 10/19/2009 DEFUELED    
Wolf Creek 1 0 10/09/2009 REFUELING OUTAGE    

Page Last Reviewed/Updated Thursday, March 25, 2021