Power Reactor Status Report for May 16, 2009
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 0 | 04/19/2009 | REFUELING OUTAGE | * | |
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | ||||
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 10 | REACTOR STARTUP | * | ||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 0 | 04/17/2009 | REFUELING OUTAGE | ||
| Salem 1 | 100 | ||||
| Salem 2 | 100 | ||||
| Seabrook 1 | 100 | ||||
| Susquehanna 1 | 80 | MAIN CONDENSER CLEANING | * | ||
| Susquehanna 2 | 8 | REACTOR STARTUP | * | ||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ||||
| Browns Ferry 2 | 0 | 04/25/2009 | REFUELING OUTAGE | * | |
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 0 | 05/10/2009 | RX SCRAM - SEE EN #45052 | ||
| Hatch 2 | 0 | 02/08/2009 | MAINTENANCE OUTAGE | ||
| McGuire 1 | 100 | ||||
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 95 | FEEDWATER CONTROL VALVE TROUBLESHOOTING | * | ||
| Oconee 2 | 100 | ||||
| Oconee 3 | 0 | 04/24/2009 | REFUELING OUTAGE | ||
| Robinson 2 | 100 | ||||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 0 | 04/26/2009 | RELOADING CORE | * | |
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 100 | * | |||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | * | |||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 100 | 72-HR ACTION STATEMENT DUE TO AUXILIARY S/U XFMR OOS DUE TO MAINTENANCE | * | ||
| Clinton | 96 | 100% ELECTRICAL CAPABILITY | * | ||
| D.C. Cook 1 | 0 | 03/02/2009 | FORCED OUTAGE - SEE EN #44507 | ||
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 100 | ||||
| Dresden 2 | 99 | 100% ELECTRICAL CAPABILITY | |||
| Dresden 3 | 100 | ||||
| Duane Arnold | 100 | ||||
| Fermi 2 | 100 | PREPARING FOR DOWNPOWER TO 65% POWER FOR PLANNED MAINTENANCE | * | ||
| Kewaunee | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 59 | HOLDING POWER FOR TESTING | |||
| Palisades | 100 | ||||
| Perry 1 | 34 | HOLDING POWER FOR MAINTENANCE ON 'A' RECIRC PUMP | * | ||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 70 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
| Prairie Island 1 | 42 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
| Prairie Island 2 | 100 | ||||
| Quad Cities 1 | 0 | 04/26/2009 | REFUELING OUTAGE | * | |
| Quad Cities 2 | 100 |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 0 | 05/08/2009 | REFUELING OUTAGE | ||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 70 | REDUCED POWER DUE TO MAINTENANCE ON SWITCHYARD BREAKER (VENUS) TO 345KV OFFSITE LINE | |||
| Cooper | 73 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 100 | ||||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 0 | 04/03/2009 | REFUELING OUTAGE | ||
| River Bend 1 | 100 | ||||
| San Onofre 2 | 99 | 100% ELECTRICAL CAPACITY | |||
| San Onofre 3 | 85 | REDUCED POWER FOR CIRC WATER BOX CLEANING | * | ||
| South Texas 1 | 100 | ||||
| South Texas 2 | 100 | ||||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021