Power Reactor Status Report for March 18, 2008

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100     *  
Ginna 100        
Hope Creek 1 100   OFFSITE LINE 5023 (500 KV) OOS    
Indian Point 2 98   COASTDOWN TO REFUELING OUTAGE LINE 13W93 OOS *  
Indian Point 3 100   LINE 13W93 OOS *  
Limerick 1 0 02/29/2008 REFUELING OUTAGE *  
Limerick 2 100        
Millstone 2 100        
Millstone 3 100   LINE 348 (345 KV) OOS UNTIL 3/21    
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 93   HOLDING POWER FOR CONTROL VALVE OSCILLATION PROBLEM AND FEEDWATER HEATER ISSUES *  
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 03/11/2008 REFUELING OUTAGE DEFUELED *  
Seabrook 1 100   369 KV NEWINGTON LINE OOS FROM 1300-1500 *  
Susquehanna 1 0 03/03/2008 REFUELING OUTAGE    
Susquehanna 2 100   VOLTAGE REGULATOR IN MANUAL    
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 31   COMMENCE REFUELING OUTAGE AT 0900 *  
Brunswick 1 0 03/14/2008 REFUELING OUTAGE *  
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 03/01/2008 DROP LINE WELD REPAIR IN PROGRESS    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 0 03/14/2008 MAINTENANCE OUTAGE    
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/01/2008 DEFUELED    
North Anna 1 100        
North Anna 2 100        
Oconee 1 73   1A1 RCP SHUT DOWN    
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100   161 KV MOCCASIN LINE OOS THRU 3/21    
Sequoyah 2 100   161 KV MOCCASIN LINE OOS THRU 3/21    
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 0 03/15/2008 REFUELING OUTAGE *  
Vogtle 2 99   100% ELECTRICAL CAPABILITY *  
Watts Bar 1 0 02/10/2008 REFUELING OUTAGE    

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 99   100% ELECTRICAL CAPABILITY; LINE 1221 (345KV) OOS WITH SWITCHING ONGOING UNTIL 3/18 *  
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY *  
Fermi 2 100   SHOAL LINE (120KV) OOS UNTIL 3/20 (1 OF 5) *  
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 60   POWER SUPPRESSION TESTING AND ROD SEQUENCE EXCHANGE *  
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 0 03/16/2008 REFUELING OUTAGE    
Prairie Island 2 100        
Quad Cities 1 97   100% ELECTRICAL OUTPUT    
Quad Cities 2 0 03/02/2008 REFUELING OUTAGE    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 03/16/2008 REFUELING OUTAGE    
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 45   INCREASING POWER *  
Cooper 90   COASTDOWN TO REFUELING OUTAGE    
Diablo Canyon 1 100   DIABLO-MESA 230 KV LINE OOS 3/11 THRU 3/18. DIABLO-GATES1 500 KV LINE OOS THRU 3/28    
Diablo Canyon 2 0 02/03/2008 DEFUELED    
Fort Calhoun 0 03/15/2008 TRIP SEE EN# 44066    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 70   TROUBLESHOOT FEEDWATER HEATER FLOW ISSUE *  
San Onofre 2 99        
San Onofre 3 100        
South Texas 1 89   COASTDOWN TO REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 03/17/2008 TRIP - SEE EN #44072 *  