Skip to main content

Power Reactor Status Report for January 27, 2008

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 64   INCREASING POWER *  
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 99   COASTDOWN TO REFUELING OUTAGE *  
Limerick 2 100        
Millstone 2 100   "D" CIRC WATER PUMP OOS.    
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 92   HOLDING POWER INDEFINITELY DUE TO TURBINE CONTROL VALVE ISSUE    
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 0 01/19/2008 FORCED OUTAGE - T/S AND REPAIR OF 345 KV BUSWORK ASSOCIATED WITH TRANSFORMER IN PROGRESS - OFFSITE POWER PROVIDED THRU RESERVE STATION TRANSFORMER    
Susquehanna 1 100        
Susquehanna 2 100   VOLTAGE REGULATOR IN MANUAL    
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 86   INCREASING POWER AFTER CONTROL ROD ADJUSTMENT *  
Browns Ferry 3 100        
Brunswick 1 86   INCREASING POWER AFTER TURBINE TESTING *  
Brunswick 2 100     *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 65   SWAPPING CONDENSATE PUMP CONTROLLER *  
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 97   COASTDOWN TO REFUELING OUTAGE *  
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 0 01/24/2008 FORCED OUTAGE    
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 97   100% ELECTRICAL CAPABILITY    
Vogtle 2 98   100% ELECTRICAL CAPABILITY    
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 0 01/11/2008 REFUELING OUTAGE    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 0 12/29/2007 REFUELING OUTAGE    
Dresden 2 97   100% ELECTRICAL CAPABILITY    
Dresden 3 97   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY.    
Fermi 2 100        
Kewaunee 100        
La Salle 1 55   REDUCED POWER FOR CONTROL ROD TESTING AND POWER SUPPRESSION *  
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 0 01/16/2008 FORCED OUTAGE - TRANSFORMER REPAIR IN PROGRESS    
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 97   100% ELECTRICAL CAPABILITY    
Quad Cities 2 96   100% ELECTRICAL CAPABILITY    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 66   INCREASING POWER TO 100% - RECIRC PUMP CONTROLLER PROBLEM - RECIRC PUMPS IN MANUAL *  
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100   230KV MORRO BAY-MIDWAY LINE OOS TIL MID MARCH - SITE CURRENTLY EXPERIENCING ADVERSE WEATHER *  
Diablo Canyon 2 99   COASTDOWN TO REFUELING OUTAGE - 230KV MORRO BAY-MIDWAY LINE OOS TIL MID MARCH - SITE CURRENTLY EXPERIENCING ADVERSE WEATHER *  
Fort Calhoun 97   HOLDING POWER TO STABILIZE PLANT FOR MODERATOR TEMPERATURE COEFFICIENT TESTING *  
Grand Gulf 1 100        
Palo Verde 1 100   PLANNED MAINTENANCE ON THE STARTUP TRANSFORMER - ESTIMATED COMPLETION 2/2/08.    
Palo Verde 2 100   PLANNED MAINTENANCE ON THE STARTUP TRANSFORMER - ESTIMATED COMPLETION 2/2/08.    
Palo Verde 3 100   PLANNED MAINTENANCE ON THE STARTUP TRANSFORMER - ESTIMATED COMPLETION 2/2/08.    
River Bend 1 0 01/06/2008 DEFUELED    
San Onofre 2 97   ADMINISTRATIVE LIMIT BASED ON STEAM GENERATOR LIMITATIONS *  
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Tuesday, August 25, 2026

Page Last Reviewed/Updated Tuesday, August 25, 2026