Power Reactor Status Report for November 27, 2007
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Beaver Valley 1 | 100 | ||||
Beaver Valley 2 | 100 | ||||
Calvert Cliffs 1 | 100 | ||||
Calvert Cliffs 2 | 100 | ||||
FitzPatrick | 100 | ||||
Ginna | 100 | ||||
Hope Creek 1 | 99 | CROSS FLOW DATA ACQUISITION IN PROGRESS. 500 KV RING BUS BREAKER 'CENTER RED' OPEN FOR MAINTENANCE. | |||
Indian Point 2 | 100 | ||||
Indian Point 3 | 100 | ||||
Limerick 1 | 100 | GENERATOR VOLTAGE REGULATOR IN MANUAL | |||
Limerick 2 | 100 | ||||
Millstone 2 | 100 | ||||
Millstone 3 | 100 | ||||
Nine Mile Point 1 | 100 | 345 KV LINE MAINTENANCE | * | ||
Nine Mile Point 2 | 95 | MOISTURE SEPARATOR REHEATERS TRIPPED AFTER RESTORATION - TROUBLESHOOTING IN PROGRESS | |||
Oyster Creek | 100 | 4 RECIRC LOOP OPERATION, 'C' RECIRC PUMP SEAL FAILURE. | |||
Peach Bottom 2 | 100 | STARTUP SOURCE 343 OOS | |||
Peach Bottom 3 | 100 | STARTUP SOURCE 343 OOS | |||
Pilgrim 1 | 100 | TRANSMISSION WORK IN VICINITY | * | ||
Salem 1 | 100 | ||||
Salem 2 | 100 | ||||
Seabrook 1 | 100 | 345 KV LINE (363) MAINTENANCE POWER REDUCTION THREAT DUE TO GRID WORK IN NEW YORK UNTIL JANUARY | * | ||
Susquehanna 1 | 100 | ||||
Susquehanna 2 | 100 | VOLTAGE REGULATOR IN MANUAL | |||
Three Mile Island 1 | 100 | ||||
Vermont Yankee | 100 |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Browns Ferry 1 | 100 | * | |||
Browns Ferry 2 | 100 | * | |||
Browns Ferry 3 | 100 | * | |||
Brunswick 1 | 100 | ||||
Brunswick 2 | 100 | ||||
Catawba 1 | 100 | ||||
Catawba 2 | 100 | ||||
Crystal River 3 | 0 | 11/02/2007 | REFUELING OUTAGE | ||
Farley 1 | 100 | ||||
Farley 2 | 100 | ||||
Harris 1 | 100 | ||||
Hatch 1 | 100 | ||||
Hatch 2 | 100 | ||||
McGuire 1 | 100 | ||||
McGuire 2 | 100 | ||||
North Anna 1 | 100 | ||||
North Anna 2 | 100 | ||||
Oconee 1 | 100 | ||||
Oconee 2 | 100 | ||||
Oconee 3 | 0 | 10/26/2007 | DEFUELED | ||
Robinson 2 | 100 | ||||
Saint Lucie 1 | 100 | ||||
Saint Lucie 2 | 0 | 09/30/2007 | DEFUELED | ||
Sequoyah 1 | 100 | ||||
Sequoyah 2 | 100 | ||||
Summer | 100 | ||||
Surry 1 | 0 | 10/20/2007 | REFUELING OUTAGE | ||
Surry 2 | 100 | ||||
Turkey Point 3 | 100 | ||||
Turkey Point 4 | 100 | ||||
Vogtle 1 | 97 | 100% ELECTRICAL CAPABILITY | |||
Vogtle 2 | 98 | 100% ELECTRICAL CAPABILITY | |||
Watts Bar 1 | 100 |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Braidwood 1 | 92 | EHC LEAK ON #2 GOVERNOR VALVE - REPAIRED, POWER ASCENSION IN-PROGRESS | * | ||
Braidwood 2 | 100 | ||||
Byron 1 | 100 | ||||
Byron 2 | 100 | ||||
Clinton | 95 | COASTDOWN TO REFUELING OUTAGE | |||
D.C. Cook 1 | 100 | ||||
D.C. Cook 2 | 100 | ||||
Davis-Besse | 100 | ||||
Dresden 2 | 97 | 100% ELECTRICAL CAPABILITY | * | ||
Dresden 3 | 98 | 100% ELECTRICAL CAPABILITY | |||
Duane Arnold | 98 | 161 KV SWITCHYARD CAPACITOR BANK MAINTENANCE 100% ELECTRICAL CAPABILITY | |||
Fermi 2 | 100 | ||||
Kewaunee | 100 | ||||
La Salle 1 | 89 | COASTDOWN TO REFUELING OUTAGE | |||
La Salle 2 | 100 | ||||
Monticello | 100 | ||||
Palisades | 100 | ||||
Perry 1 | 100 | ||||
Point Beach 1 | 100 | ||||
Point Beach 2 | 100 | ||||
Prairie Island 1 | 100 | ||||
Prairie Island 2 | 100 | ||||
Quad Cities 1 | 97 | 100% ELECTRICAL CAPABILITY | |||
Quad Cities 2 | 96 | 100% ELECTRICAL CAPABILITY |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Arkansas Nuclear 1 | 100 | ||||
Arkansas Nuclear 2 | 100 | ||||
Callaway | 100 | ||||
Columbia Generating Station | 100 | ||||
Comanche Peak 1 | 100 | ||||
Comanche Peak 2 | 100 | ||||
Cooper | 100 | ||||
Diablo Canyon 1 | 100 | ||||
Diablo Canyon 2 | 100 | ||||
Fort Calhoun | 100 | ||||
Grand Gulf 1 | 100 | SERVICE TRANSFORMER 11 OOS | * | ||
Palo Verde 1 | 0 | 11/23/2007 | FORCED OUTAGE - TS REQUIRED SHUTDOWN DUE TO INOPERABLE AUTOMATIC LOAD SEQUENCER - SEE EVENT #43804 | ||
Palo Verde 2 | 100 | ||||
Palo Verde 3 | 0 | 09/29/2007 | DEFUELED | ||
River Bend 1 | 80 | HOLDING FOR SCHEDULED MAINTENANCE | |||
San Onofre 2 | 0 | 11/26/2007 | REFUELING OUTAGE | * | |
San Onofre 3 | 100 | ||||
South Texas 1 | 100 | ||||
South Texas 2 | 100 | ||||
Waterford 3 | 100 | ||||
Wolf Creek 1 | 100 |