Power Reactor Status Report for March 26, 2007
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 82 | REDUCED FOR WATER BOX CLEANING | |||
| Beaver Valley 2 | 99 | ONE TGV ISOLATED FOR MAINTENANCE | |||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 0 | 02/25/2007 | REFUELING OUTAGE | ||
| FitzPatrick | 100 | 115 KV LINE OOS FOR MAINTENANCE | |||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | ||||
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 0 | 03/06/2007 | REFUELING OUTAGE | ||
| Limerick 1 | 100 | ||||
| Limerick 2 | 0 | 03/09/2007 | REFUELING OUTAGE AND SWITCHYARD WORK | * | |
| Millstone 2 | 100 | RING BUS RELAY WORK IN SWITCHYARD 3/26 - 4/5 | * | ||
| Millstone 3 | 100 | RING BUS RELAY WORK IN SWITCHYARD 3/26 - 4/5 | * | ||
| Nine Mile Point 1 | 0 | 03/16/2007 | REFUELING OUTAGE ALSO LINE 4 OOS AND 345KV BKR OOS FOR MAINTENANCE | * | |
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 91 | RECIRC PUMP SEAL MONITORING | * | ||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 84 | COASTDOWN TO REFUELING OUTAGE STARTUP XFRMR OUTAGE ENDING THIS EVENING | * | ||
| Salem 1 | 86 | COASTDOWN TO REFUELING OUTAGE | |||
| Salem 2 | 100 | ||||
| Seabrook 1 | 96 | HIGH TEMPERATURE ON NEUTRAL BUS BUSHING | * | ||
| Susquehanna 1 | 100 | MAIN GENERATOR VOLTAGE REGULATOR IN MANUAL | |||
| Susquehanna 2 | 0 | 03/03/2007 | REFUELING OUTAGE | ||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 94 | INCREASING POWER FOLLOWING SWITCHYARD BREAKER WORK | * |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 0 | 03/03/1985 | 500 KV (MADISON) LINES OOS | ||
| Browns Ferry 2 | 0 | 02/20/2007 | REFUELING OUTAGE 500 KV (MADISON) LINES OOS | ||
| Browns Ferry 3 | 100 | 500 KV (MADISON) LINES OOS | |||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 0 | 03/02/2007 | REFUELING OUTAGE | ||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | SWITCHYARD BREAKER WORK | * | ||
| Farley 2 | 100 | SWITCHYARD BREAKER WORK | * | ||
| Harris 1 | 100 | ||||
| Hatch 1 | 100 | ||||
| Hatch 2 | 95 | INCREASING POWER | * | ||
| McGuire 1 | 0 | 03/10/2007 | DEFUELED | ||
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 0 | 03/17/2007 | REFUELING OUTAGE | ||
| Oconee 1 | 100 | ||||
| Oconee 2 | 100 | ||||
| Oconee 3 | 100 | ||||
| Robinson 2 | 96 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 98 | 100% ELECTRICAL CAPABILITY, OFFSITE SOURCE TEST ON 3/27/07 | * | ||
| Vogtle 2 | 0 | 03/03/2007 | DEFUELED, OFFSITE SOURCE TEST ON 3/27/07 | * | |
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 93 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Clinton | 97 | 100% ELECTRICAL CAPABILITY | |||
| D.C. Cook 1 | 100 | ||||
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 91 | HOLDING POWER - COND PUMP MAINT | * | ||
| Dresden 2 | 98 | 100% ELECTRICAL CAPABILITY | * | ||
| Dresden 3 | 98 | 100% ELECTRICAL CAPABILITY | * | ||
| Duane Arnold | 100 | HOLDING FOR XENON BUILD-IN | * | ||
| Fermi 2 | 100 | ||||
| Kewaunee | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 0 | 03/13/2007 | REFUELING OUTAGE | ||
| Palisades | 95 | MAIN STEAM SYSTEM ISSUE | * | ||
| Perry 1 | 96 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | 345 KV OFFSITE PWR LINE OOS UNTIL 1ST WEEK IN MAY | |||
| Prairie Island 2 | 100 | 345 KV OFFSITE PWR LINE OOS UNTIL 1ST WEEK IN MAY | |||
| Quad Cities 1 | 92 | COASTDOWN TO REFUELING OUTAGE | |||
| Quad Cities 2 | 96 | 100% ELECTRICAL CAPABILITY |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 85 | TSO REQUEST TO POWER DOWN | * | ||
| Comanche Peak 1 | 0 | 02/24/2007 | DEFUELED | ||
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 100 | ||||
| Grand Gulf 1 | 0 | 03/18/2007 | REFUELING OUTAGE | ||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 100 | ||||
| River Bend 1 | 100 | ||||
| San Onofre 2 | 99 | ||||
| San Onofre 3 | 100 | ||||
| South Texas 1 | 100 | ||||
| South Texas 2 | 0 | 03/25/2007 | REFUELING OUTAGE | * | |
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |