Power Reactor Status Report for January 26, 2007

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 15   MAIN GENERATOR TAKEN OFFLINE DUE TO 345KV LINE GAS LEAK BETWEEN BREAKERS 11 & 163 *  
Susquehanna 1 100   GENERATOR VOLTAGE REGULATOR IN MANUAL    
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 CORE LOADED CAVITY FLOODED 500 KV (TRINITY) LINE OUT OF SERVICE    
Browns Ferry 2 96   COASTDOWN TO REFUELING OUTAGE 500 KV (TRINITY) LINE OUT OF SERVICE    
Browns Ferry 3 100   500 KV (TRINITY) LINE OUT OF SERVICE    
Brunswick 1 100        
Brunswick 2 100     *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 90   HOLDING FOR MAIN TURBINE CONTROL VALVE PROBLEM    
Hatch 2 99   COASTDOWN TO REFUELING OUTAGE *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100     *  
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 98   100% ELECTRICAL CAPABILITY    
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 97   100% ELECTRICAL CAPABILITY    
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY COASTDOWN TO REFUELING OUTAGE *  
Fermi 2 100        
Kewaunee 92   HEATER DRAIN PUMP MAINTENANCE LIMITED TO 99% FOR FEED FLOW MEASURING INSTRUMENT CALIBRATION    
La Salle 1 100        
La Salle 2 96   COASTDOWN TO REFUELING OUTAGE    
Monticello 100     *  
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 97   100% ELECTRICAL CAPABILITY    
Quad Cities 2 95   100% ELECTRICAL CAPABILITY    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 01/25/2007 FORCED OUTAGE - TECH SPEC REQUIRED SHUTDOWN DUE TO DROPPED CEA - SEE EN#43121 *  
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 60   'B' REACTOR RECIRC MG SET TRIP - REPAIRS IN PROGRESS - EXPECT RECIRC PUMP RESTART AT APPROX. 0800 HRS *  
Diablo Canyon 1 100   SWITCHING OF 230KV LINES SCHEDULED FOR 1/25 - WILL NOT AFFECT OFFSITE POWER AVAILABILITY    
Diablo Canyon 2 100   SWITCHING OF 230KV LINES SCHEDULED FOR 1/25 - WILL NOT AFFECT OFFSITE POWER AVAILABILITY    
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 99   INCREASING POWER TO 100% *  
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 99   STEAM GENERATOR TUBE PLUGGING LIMITATION    
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        