Power Reactor Status Report for October 14, 2006
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 100 | ||||
| Beaver Valley 2 | 0 | 10/01/2006 | REFUELING OUTAGE - DEFUELED | ||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 0 | 10/08/2006 | REFUELING OUTAGE | ||
| Ginna | 0 | 10/08/2006 | REFUELING OUTAGE | ||
| Hope Creek 1 | 100 | PEACH BOTTOM TRANSMISSION LINE 5014 (500 KV) OUTAGE. WILL USE DIFFERENT VAR CURVES FOR LOADING OF GENERATOR. | |||
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 100 | ||||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 0 | 10/06/2006 | REFUELING OUTAGE | ||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 90 | COASTDOWN TO REFUELING OUTAGE | |||
| Peach Bottom 2 | 69 | INCREASING POWER FOLLOWING ROD PATTERN ADJUSTMENT. WILL OPEN ONE GENERATOR OUTPUT BREAKER TO SUPPORT WORK ON 5014 (500KV) SWITCHING TRANSMISSION LINE. | * | ||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 100 | PEACH BOTTOM TRANSMISSION LINE 5014 (500 KV) OUTAGE. WILL USE DIFFERENT VAR CURVES FOR LOADING OF GENERATOR. | |||
| Salem 2 | 0 | 10/10/2006 | REFUELING OUTAGE | * | |
| Seabrook 1 | 0 | 09/30/2006 | REFUELING OUTAGE - DEFUELED | ||
| Susquehanna 1 | 100 | ||||
| Susquehanna 2 | 0 | 09/29/2006 | PLANNED RE-CHANNELING OUTAGE | ||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 0 | 03/03/1985 | DEFUELED | ||
| Browns Ferry 2 | 0 | 10/10/2006 | MAINTENANCE OUTAGE | ||
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 91 | GOVERNOR VALVE TESTING | * | ||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 100 | ||||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 0 | 09/16/2006 | REFUELING OUTAGE | ||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 0 | 10/06/2006 | REFUELING OUTAGE | ||
| Oconee 2 | 100 | ||||
| Oconee 3 | 100 | ||||
| Robinson 2 | 100 | ||||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 60 | REPAIR SERVICE WATER LEAK TO TURBINE COOLING HEAT EXCHANGER | * | ||
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 0 | 10/13/2006 | REFUELING OUTAGE | * | |
| Surry 1 | 100 | ||||
| Surry 2 | 0 | 10/07/2006 | REFUELING OUTAGE | * | |
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | * | |||
| Vogtle 1 | 0 | 09/16/2006 | REFUELING OUTAGE | ||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 0 | 09/10/2006 | DEFUELED - REPLACING ALL 4 STEAM GENERATORS |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 92 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Byron 1 | 0 | 09/10/2006 | REFUELING OUTAGE | ||
| Byron 2 | 100 | ||||
| Clinton | 96 | 100% ELECTRICAL CAPABILITY | |||
| D.C. Cook 1 | 0 | 09/15/2006 | DEFUELED | ||
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 100 | ||||
| Dresden 2 | 98 | 100% ELECTRICAL CAPABILITY | * | ||
| Dresden 3 | 99 | 100% ELECTRICAL CAPABILITY | |||
| Duane Arnold | 96 | 100% ELECTRICAL CAPABILITY | |||
| Fermi 2 | 100 | ||||
| Kewaunee | 0 | 09/02/2006 | REFUELING OUTAGE | ||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 62 | CONTROL ROD SEQUENCE | * | ||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 100 | ||||
| Quad Cities 1 | 96 | 100% ELECTRICAL CAPABILITY | * | ||
| Quad Cities 2 | 96 | 100% ELECTRICAL CAPABILITY |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 0 | 09/19/2006 | DEFUELED | ||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 0 | 10/07/2006 | REFUELING OUTAGE | ||
| Cooper | 94 | COASTDOWN TO REFUELING OUTAGE. | |||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 0 | 09/09/2006 | DEFUELED | ||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 0 | 09/19/2006 | PREPARING FOR STARTUP | ||
| Palo Verde 2 | 0 | 09/29/2006 | REFUELING OUTAGE | ||
| Palo Verde 3 | 100 | ||||
| River Bend 1 | 61 | CONTROL ROD SEQUENCE | * | ||
| San Onofre 2 | 99 | STEAM GENERATOR TUBE PLUGGING LIMITATION | |||
| San Onofre 3 | 94 | COASTDOWN TO REFUELING OUTAGE | |||
| South Texas 1 | 0 | 09/30/2006 | DEFUELED | ||
| South Texas 2 | 100 | ||||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 0 | 10/06/2006 | REFUELING OUTAGE |
Page Last Reviewed/Updated Tuesday, August 25, 2026
Page Last Reviewed/Updated Tuesday, August 25, 2026