Power Reactor Status Report for October 12, 2006
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Beaver Valley 1 | 100 | ||||
Beaver Valley 2 | 0 | 10/01/2006 | REFUELING OUTAGE - DEFUELED | ||
Calvert Cliffs 1 | 100 | ||||
Calvert Cliffs 2 | 100 | ||||
FitzPatrick | 0 | 10/08/2006 | REFUELING OUTAGE | ||
Ginna | 0 | 10/08/2006 | REFUELING OUTAGE | ||
Hope Creek 1 | 100 | PEACH BOTTOM TRANSMISSION LINE 5014 (500 KV) OUTAGE. WILL USE DIFFERENT VAR CURVES FOR LOADING OF GENERATOR. | * | ||
Indian Point 2 | 100 | ||||
Indian Point 3 | 100 | ||||
Limerick 1 | 100 | ||||
Limerick 2 | 100 | ||||
Millstone 2 | 0 | 10/06/2006 | REFUELING OUTAGE | ||
Millstone 3 | 100 | ||||
Nine Mile Point 1 | 100 | ||||
Nine Mile Point 2 | 100 | ||||
Oyster Creek | 90 | COASTDOWN TO REFUELING OUTAGE | * | ||
Peach Bottom 2 | 50 | HOLDING POWER LEVEL FOR INVESTIGATION OF HYDROGEN SEAL OIL ISSUE. WILL HAVE TO OPEN ONE GENERATOR OUTPUT BREAKER TO SUPPORT WORK ON 5014 (500KV) SWITCHING TRANSMISSION LINE. | * | ||
Peach Bottom 3 | 100 | WILL HAVE TO OPEN ONE GENERATOR OUTPUT BREAKER TO SUPPORT WORK ON 5014 (500KV) SWITCHING TRANSMISSION LINE. | * | ||
Pilgrim 1 | 80 | INCREASING POWER AFTER PLANNED MAINTENANCE, THERMAL BACKWASH. | * | ||
Salem 1 | 100 | PEACH BOTTOM TRANSMISSION LINE 5014 (500 KV) OUTAGE. WILL USE DIFFERENT VAR CURVES FOR LOADING OF GENERATOR. | * | ||
Salem 2 | 0 | 10/10/2006 | REFUELING OUTAGE. PEACH BOTTOM TRANSMISSION LINE 5014 (500 KV) OUTAGE. | * | |
Seabrook 1 | 0 | 09/30/2006 | REFUELING OUTAGE | ||
Susquehanna 1 | 100 | ||||
Susquehanna 2 | 0 | 09/29/2006 | PLANNED RE-CHANNELING OUTAGE | ||
Three Mile Island 1 | 100 | ||||
Vermont Yankee | 100 |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Browns Ferry 1 | 0 | 03/03/1985 | DEFUELED | ||
Browns Ferry 2 | 0 | 10/10/2006 | REFUELING OUTAGE | * | |
Browns Ferry 3 | 100 | ||||
Brunswick 1 | 100 | ||||
Brunswick 2 | 100 | ||||
Catawba 1 | 100 | ||||
Catawba 2 | 100 | ||||
Crystal River 3 | 100 | ||||
Farley 1 | 100 | ||||
Farley 2 | 100 | ||||
Harris 1 | 100 | ||||
Hatch 1 | 100 | ||||
Hatch 2 | 100 | ||||
McGuire 1 | 100 | ||||
McGuire 2 | 0 | 09/16/2006 | REFUELING OUTAGE | * | |
North Anna 1 | 100 | ||||
North Anna 2 | 100 | ||||
Oconee 1 | 0 | 10/06/2006 | REFUELING OUTAGE | ||
Oconee 2 | 100 | ||||
Oconee 3 | 100 | ||||
Robinson 2 | 100 | ||||
Saint Lucie 1 | 100 | ||||
Saint Lucie 2 | 100 | ||||
Sequoyah 1 | 100 | ||||
Sequoyah 2 | 100 | ||||
Summer | 80 | PRE-OUTAGE MAINTENANCE IN PROGRESS | * | ||
Surry 1 | 100 | ||||
Surry 2 | 0 | 10/07/2006 | WILL NOT RESTART BEFORE OUTAGE. | * | |
Turkey Point 3 | 100 | ||||
Turkey Point 4 | 75 | FEEDWATER LEVEL CONTROL SYSTEM REPAIR | * | ||
Vogtle 1 | 0 | 09/16/2006 | REFUELING OUTAGE | * | |
Vogtle 2 | 100 | ||||
Watts Bar 1 | 0 | 09/10/2006 | DEFUELED - REPLACING ALL 4 STEAM GENERATORS |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Braidwood 1 | 100 | ||||
Braidwood 2 | 93 | COASTDOWN TO REFUELING OUTAGE | |||
Byron 1 | 0 | 09/10/2006 | REFUELING OUTAGE | ||
Byron 2 | 100 | ||||
Clinton | 96 | 100% ELECTRICAL CAPABILITY | * | ||
D.C. Cook 1 | 0 | 09/15/2006 | DEFUELED | ||
D.C. Cook 2 | 100 | ||||
Davis-Besse | 100 | ||||
Dresden 2 | 99 | 100% ELECTRICAL CAPABILITY | |||
Dresden 3 | 100 | * | |||
Duane Arnold | 96 | 100% ELECTRICAL CAPABILITY | |||
Fermi 2 | 100 | ||||
Kewaunee | 0 | 09/02/2006 | REFUELING OUTAGE | ||
La Salle 1 | 100 | ||||
La Salle 2 | 100 | ||||
Monticello | 100 | ||||
Palisades | 100 | ||||
Perry 1 | 100 | ||||
Point Beach 1 | 100 | ||||
Point Beach 2 | 100 | ||||
Prairie Island 1 | 100 | ||||
Prairie Island 2 | 100 | ||||
Quad Cities 1 | 97 | 100% ELECTRICAL CAPABILITY | |||
Quad Cities 2 | 96 | 100% ELECTRICAL CAPABILITY |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Arkansas Nuclear 1 | 100 | ||||
Arkansas Nuclear 2 | 0 | 09/19/2006 | DEFUELED | ||
Callaway | 100 | ||||
Columbia Generating Station | 100 | ||||
Comanche Peak 1 | 100 | ||||
Comanche Peak 2 | 0 | 10/07/2006 | REFUELING OUTAGE | ||
Cooper | 95 | COASTDOWN TO REFUELING OUTAGE. NEBRASKA CITY LINE, 345 KV, OUT OF SERVICE FOR PLANNED MAINTENANCE. | |||
Diablo Canyon 1 | 100 | ||||
Diablo Canyon 2 | 100 | ||||
Fort Calhoun | 0 | 09/09/2006 | DEFUELED | * | |
Grand Gulf 1 | 100 | ||||
Palo Verde 1 | 0 | 09/19/2006 | PREPARING FOR STARTUP | * | |
Palo Verde 2 | 0 | 09/29/2006 | REFUELING OUTAGE | ||
Palo Verde 3 | 100 | ||||
River Bend 1 | 100 | ||||
San Onofre 2 | 99 | STEAM GENERATOR TUBE PLUGGING LIMITATION | |||
San Onofre 3 | 96 | COASTDOWN TO REFUELING OUTAGE | * | ||
South Texas 1 | 0 | 09/30/2006 | DEFUELED | * | |
South Texas 2 | 100 | ||||
Waterford 3 | 100 | ||||
Wolf Creek 1 | 0 | 10/06/2006 | REFUELING OUTAGE |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021