Skip to main content

Power Reactor Status Report for March 30, 2002

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 95   HOLDING POWER AT THIS LEVEL DUE TO HIGH FEEDWATER PUMP BEARING TEMPERATURES *  
BEAVER VALLEY 2 40   HOLDING POWER AT THIS LEVEL TO REPACK THE 'A' AND 'B' HEATER DRAIN PUMPS *  
CALVERT CLIFFS 1 0 02/15/2002 REFUELING OUTAGE - DEFUELED    
CALVERT CLIFFS 2 100        
FITZPATRICK 1 100        
GINNA 1 0 03/18/2002 REFUELING OUTAGE - DEFUELED    
HOPE CREEK 1 100        
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 0 02/15/2002 REFUELING OUTAGE - PREPARING FOR STARTUP *  
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 0 03/15/2002 REFUELING OUTAGE - SECOND PHASE OF FUEL SHUFFLE IN PROGRESS *  
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100     *  
PILGRIM 1 100     *  
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 0 03/02/2002 REFUELING OUTAGE - REFUELED    
SUSQUEHANNA 2 38   INCREASING POWER AFTER DECREASING TO 30% POWER TO PERFORM WATERBOX CLEANING *  
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 82   SLOWLY INCREASING POWER TO 91% AFTER DECREASING TO APPROXIMATELY 58% TO PERFORM POWER SUPPRESSION TESTING AND SINGLE ROD SCRAM TIME TESTING - PLAN TO HOLD POWER AT 91% DUE TO FUEL PIN LEAKS *  

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 0 03/26/2002 REFUELING OUTAGE - FIRST PHASE OF FUEL OFFLOAD COMPLETE *  
BRUNSWICK 1 5   REFUELING OUTAGE - STARTUP IN PROGRESS *  
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 100        
HARRIS 1 100        
HATCH 1 0 03/23/2002 REFUELING OUTAGE - FIRST PHASE OF FUEL OFFLOAD COMPLETE *  
HATCH 2 100        
MCGUIRE 1 100        
MCGUIRE 2 78   HOLDING POWER AT THIS LEVEL TO PERFORM FLUX MAPPING AFTER EXITING A REFUELING OUTAGE *  
NORTH ANNA 1 100        
NORTH ANNA 2 100        
OCONEE 1 0 03/23/2002 REFUELING OUTAGE - PREPARING FOR FUEL OFFLOAD (TONIGHT) *  
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 0 03/24/2002 REFUELING OUTAGE - PREPARING FOR FUEL OFFLOAD *  
TURKEY POINT 3 100        
TURKEY POINT 4 0 03/23/2002 REFUELING OUTAGE - DEFUELED *  
VOGTLE 1 0 03/06/2002 REFUELING OUTAGE - FUEL OFFLOAD SUSPENDED DUE TO A NUCLEAR INSTRUMENT SOURCE RANGE PROBLEM *  
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 96   100% ELECTRICAL CAPABILITY    
BYRON 1 15   PREPARING TO PLACE THE UNIT ON LINE TO EXIT A REFUELING OUTAGE *  
BYRON 2 100   MEASURED STEAM GENERATOR TUBE LEAKAGE LESS THAN 5 GPD    
CLINTON 1 96   COASTDOWN TO REFUELING OUTAGE *  
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 0 02/15/2002 REFUELING OUTAGE - REFUELED    
DRESDEN 2 95   100% ELECTRICAL CAPABILITY    
DRESDEN 3 100        
DUANE ARNOLD 1 93   100% ELECTRICAL CAPABILITY *  
FERMI 2 54   HOLDING POWER AT THIS LEVEL IN SINGLE LOOP OPERATIONS DUE TO A RECIRCULATION PUMP MOTOR-GENERATOR SET TRIP - CURRENTLY STABILIZING AND VERIFYING THERMAL LIMITS *  
KEWAUNEE 1 100        
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 100        
PALISADES 1 100        
PERRY 1 100        
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 0 03/29/2002 MAINTENANCE OUTAGE - PROCEEDING TO MODE 4 (COLD SHUTDOWN) *  

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 95   COASTDOWN TO REFUELING OUTAGE    
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 98        
GRAND GULF 1 100        
PALO VERDE 1 99        
PALO VERDE 2 0 03/15/2002 REFUELING OUTAGE - DEFUELED    
PALO VERDE 3 99        
RIVER BEND 1 100        
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WATERFORD 3 0 03/22/2002 REFUELING OUTAGE - PREPARING FOR FUEL OFFLOAD *  
WOLF CREEK 1 0 03/23/2002 REFUELING OUTAGE - PREPARING FOR FUEL OFFLOAD (DAY SHIFT) *  

Page Last Reviewed/Updated Thursday, March 25, 2021