Power Reactor Status Report for December 6, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 100        
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 41   DECREASING TO 20% POWER TO PERFORM A DRYWELL INSPECTION *  
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 92   INCREASING TO 95% POWER TO MONITOR THE 'A' CIRCULATING PUMP FOR POSSIBLE VIBRATION *  
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 2   MAINTENANCE OUTAGE - STARTUP IN PROGRESS *  
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100        
THREE MILE ISLAND 1 5   REFUELING OUTAGE - HOLDING POWER AT THIS LEVEL *  
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 0 12/05/2001 MAINTENANCE OUTAGE *  
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 95   LOAD FOLLOWING *  
HARRIS 1 0 09/21/2001 REFUELING OUTAGE - REFUELED    
HATCH 1 100        
HATCH 2 100        
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 10/28/2001 MAINTENANCE OUTAGE    
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 0 11/10/2001 REFUELING OUTAGE - REFUELED    
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 0 11/25/2001 REFUELING OUTAGE - PREPARING TO COMMENCE A FUEL SHUFFLE *  
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 0 10/14/2001 REFUELING OUTAGE - CRITICAL - COMPLETING LOW POWER PHYSICS TESTING *  
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 96   100% ELECTRICAL EQUIVALENT    
BYRON 1 99        
BYRON 2 100        
CLINTON 1 100        
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 100        
DRESDEN 2 99     *  
DRESDEN 3 98   SLOWLY INCREASING POWER AFTER EXITING A MAINTENANCE OUTAGE *  
DUANE ARNOLD 1 93   HOLDING POWER AT MAXIMUM PER INTERIM POWER UPRATE    
FERMI 2 0 12/06/2001 MANUAL REACTOR SCRAM FROM 100% POWER DUE TO A LOSS OF STATOR WATER COOLING (Refer to event #38542) * 1
KEWAUNEE 1 28   PERFORMING A CHEMISTRY HOLD AFTER EXITING A REFUELING/MAINTENANCE OUTAGE    
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 0 11/03/2001 REFUELING OUTAGE - REFUELED    
PALISADES 1 0 06/20/2001 MAINTENANCE OUTAGE    
PERRY 1 100        
POINT BEACH 1 98        
POINT BEACH 2 98        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 0 12/03/2001 MAINTENANCE OUTAGE - APPROACHING CRITICALITY *  
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 0 11/03/2001 REFUELING OUTAGE - IN BETWEEN FUEL MOVES - MOVING CONTROL ROD BLADES    
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 99        
PALO VERDE 2 98     *  
PALO VERDE 3 99        
RIVER BEND 1 100        
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WATERFORD 3 100        
WOLF CREEK 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Wednesday, March 24, 2021