Skip to main content

Power Reactor Status Report for October 28, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 50   INCREASING POWER AFTER EXITING A MAINTENANCE OUTAGE *  
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 0 10/09/2001 REFUELING OUTAGE *  
INDIAN POINT 2 0 10/26/2001 MAINTENANCE OUTAGE *  
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 100        
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 0 10/23/2001 MAINTENANCE OUTAGE *  
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100        
THREE MILE ISLAND 1 0 10/08/2001 REFUELING OUTAGE - DEFUELED *  
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 99   HOLDING POWER AT THIS LEVEL TO PERFORM CONDENSATE SYSTEM WORK AFTER EXITING A REFUELING OUTAGE *  
CRYSTAL RIVER 3 94   INCREASING POWER AFTER EXITING A REFUELING OUTAGE *  
FARLEY 1 0 10/05/2001 REFUELING OUTAGE    
FARLEY 2 100        
HARRIS 1 0 09/21/2001 REFUELING OUTAGE - DEFUELED    
HATCH 1 100        
HATCH 2 0 10/26/2001 REACTOR SCRAM FROM 100% POWER (Refer to event #38432) *  
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 10/28/2001 MAINTENANCE OUTAGE - PREPARING TO COOL DOWN TO PERFORM A HEAD INSPECTION TO ENSURE THAT THERE ARE NO CONOSEAL OR WELD LEAKS *  
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100     *  
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 0 10/21/2001 REFUELING OUTAGE - FUEL OFFLOAD IN PROGRESS *  
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 0 10/14/2001 REFUELING OUTAGE - DEFUELED    
SURRY 2 100        
TURKEY POINT 3 35   SLOWLY INCREASING POWER AFTER EXITING A REFUELING OUTAGE *  
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 83   HOLDING POWER AT THIS LEVEL DUE TO TURBINE GENERATOR VIBRATION *  
BYRON 1 99   100% OF RATED ELECTRICAL CAPABILITY    
BYRON 2 100        
CLINTON 1 100        
COOK 1 92   HOLDING POWER AT THIS LEVEL TO EVALUATE A CIRCULATING WATER PUMP PROBLEM *  
COOK 2 55   HOLDING POWER AT THIS LEVEL TO PERFORM MAIN FEEDWATER PUMP CONDENSER WATERBOX CLEANING *  
DAVIS BESSE 1 100        
DRESDEN 2 0 10/20/2001 REFUELING OUTAGE - FUEL OFFLOAD IN PROGRESS *  
DRESDEN 3 100        
DUANE ARNOLD 1 100        
FERMI 2 0 10/27/2001 REFUELING OUTAGE *  
KEWAUNEE 1 0 09/23/2001 REFUELING OUTAGE - DEFUELED    
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 92   COASTDOWN TO REFUELING OUTAGE    
PALISADES 1 0 06/20/2001 MAINTENANCE OUTAGE    
PERRY 1 70   HOLDING POWER AT THIS LEVEL TO PERFORM TURBINE VALVE TESTING AND ROD SCRAM TIME TESTING *  
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 95   COASTDOWN TO REFUELING OUTAGE *  
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 99     *  
PALO VERDE 2 0 10/10/2001 MAINTENANCE OUTAGE *  
PALO VERDE 3 0 09/28/2001 REFUELING OUTAGE    
RIVER BEND 1 0 10/26/2001 MAINTENANCE OUTAGE *  
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100     *  
SOUTH TEXAS 2 100        
WATERFORD 3 100        
WOLF CREEK 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021