| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BEAVER VALLEY 1 | 100 | ||||
| BEAVER VALLEY 2 | 100 | ||||
| CALVERT CLIFFS 1 | 100 | ||||
| CALVERT CLIFFS 2 | 100 | ||||
| FITZPATRICK 1 | 100 | ||||
| GINNA 1 | 100 | ||||
| HOPE CREEK 1 | 0 | 10/09/2001 | REFUELING OUTAGE | ||
| INDIAN POINT 2 | 100 | ||||
| INDIAN POINT 3 | 100 | ||||
| LIMERICK 1 | 100 | ||||
| LIMERICK 2 | 100 | ||||
| MILLSTONE 2 | 100 | ||||
| MILLSTONE 3 | 100 | ||||
| NINE MILE POINT 1 | 100 | ||||
| NINE MILE POINT 2 | 100 | ||||
| OYSTER CREEK 1 | 100 | ||||
| PEACH BOTTOM 2 | 0 | 10/23/2001 | REACTOR SCRAM - SEE EVENT #38419 | * | 1 |
| PEACH BOTTOM 3 | 100 | ||||
| PILGRIM 1 | 100 | ||||
| SALEM 1 | 100 | * | |||
| SALEM 2 | 99 | * | |||
| SEABROOK 1 | 100 | ||||
| SUSQUEHANNA 1 | 100 | ||||
| SUSQUEHANNA 2 | 100 | ||||
| THREE MILE ISLAND 1 | 0 | 10/08/2001 | REFUELING OUTAGE | ||
| VERMONT YANKEE 1 | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BROWNS FERRY 1 | 0 | 03/03/1985 | DEFUELED | ||
| BROWNS FERRY 2 | 100 | ||||
| BROWNS FERRY 3 | 100 | ||||
| BRUNSWICK 1 | 100 | ||||
| BRUNSWICK 2 | 100 | ||||
| CATAWBA 1 | 100 | ||||
| CATAWBA 2 | 55 | INCREASING POWER | * | ||
| CRYSTAL RIVER 3 | 0 | 09/29/2001 | REFUELING OUTAGE | ||
| FARLEY 1 | 0 | 10/05/2001 | REFUELING OUTAGE - CORE RELOAD IN PROGRESS | ||
| FARLEY 2 | 100 | ||||
| HARRIS 1 | 0 | 09/21/2001 | REFUELING OUTAGE - DEFUELED | ||
| HATCH 1 | 100 | ||||
| HATCH 2 | 50 | INCREASING POWER | * | ||
| MCGUIRE 1 | 100 | ||||
| MCGUIRE 2 | 100 | ||||
| NORTH ANNA 1 | 100 | ||||
| NORTH ANNA 2 | 100 | ||||
| OCONEE 1 | 100 | ||||
| OCONEE 2 | 100 | ||||
| OCONEE 3 | 100 | ||||
| ROBINSON 2 | 100 | ||||
| SAINT LUCIE 1 | 100 | ||||
| SAINT LUCIE 2 | 100 | ||||
| SEQUOYAH 1 | 0 | 10/21/2001 | REFUELING OUTAGE | ||
| SEQUOYAH 2 | 100 | ||||
| SUMMER 1 | 100 | ||||
| SURRY 1 | 0 | 10/14/2001 | REFUELING OUTAGE - DEFUELED | ||
| SURRY 2 | 100 | ||||
| TURKEY POINT 3 | 0 | 09/29/2001 | REFUELING OUTAGE | * | |
| TURKEY POINT 4 | 100 | ||||
| VOGTLE 1 | 100 | ||||
| VOGTLE 2 | 100 | ||||
| WATTS BAR 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BRAIDWOOD 1 | 100 | ||||
| BRAIDWOOD 2 | 83 | TURBINE GENERATOR VIBRATION LIMIT | * | ||
| BYRON 1 | 99 | 100% OF RATED ELECTRICAL CAPABILITY | |||
| BYRON 2 | 100 | ||||
| CLINTON 1 | 100 | ||||
| COOK 1 | 100 | ||||
| COOK 2 | 100 | ||||
| DAVIS BESSE 1 | 99 | * | |||
| DRESDEN 2 | 0 | 10/20/2001 | REFUELING OUTAGE | ||
| DRESDEN 3 | 100 | ||||
| DUANE ARNOLD 1 | 40 | INCREASING POWER | * | ||
| FERMI 2 | 97 | REDUCED POWER - THERMAL LIMIT | |||
| KEWAUNEE 1 | 0 | 09/23/2001 | REFUELING OUTAGE - DEFUELED | ||
| LASALLE 1 | 100 | ||||
| LASALLE 2 | 100 | ||||
| MONTICELLO 1 | 0 | 10/23/2001 | REACTOR SCRAM - SEE EVENT #38420 | * | 1 |
| PALISADES 1 | 0 | 06/20/2001 | MAINTENANCE OUTAGE | ||
| PERRY 1 | 100 | ||||
| POINT BEACH 1 | 67 | REDUCED POWER FOR LOAD DISPATCH | * | ||
| POINT BEACH 2 | 100 | ||||
| PRAIRIE ISLAND 1 | 100 | ||||
| PRAIRIE ISLAND 2 | 100 | ||||
| QUAD CITIES 1 | 100 | ||||
| QUAD CITIES 2 | 100 |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| ARKANSAS NUCLEAR 1 | 100 | ||||
| ARKANSAS NUCLEAR 2 | 100 | ||||
| CALLAWAY 1 | 100 | ||||
| COLUMBIA GENERATING | 100 | ||||
| COMANCHE PEAK 1 | 100 | ||||
| COMANCHE PEAK 2 | 100 | ||||
| COOPER 1 | 97 | COASTDOWN TO REFUELING OUTAGE | |||
| DIABLO CANYON 1 | 100 | ||||
| DIABLO CANYON 2 | 100 | ||||
| FT CALHOUN 1 | 100 | ||||
| GRAND GULF 1 | 100 | ||||
| PALO VERDE 1 | 99 | ||||
| PALO VERDE 2 | 0 | 10/10/2001 | MAINTENANCE OUTAGE - PERFORMING CONTROL ELEMENT ASSEMBLY REPLACEMENTS | ||
| PALO VERDE 3 | 0 | 09/28/2001 | REFUELING OUTAGE - CORE RELOAD IN PROGRESS | ||
| RIVER BEND 1 | 100 | ||||
| SAN ONOFRE 2 | 64 | INCREASING POWER | * | ||
| SAN ONOFRE 3 | 100 | ||||
| SOUTH TEXAS 1 | 8 | SLOWLY INCREASING POWER | * | ||
| SOUTH TEXAS 2 | 100 | ||||
| WATERFORD 3 | 100 | ||||
| WOLF CREEK 1 | 100 |