Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for April 21, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 0 04/20/2001 MAINTENANCE OUTAGE *  
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 0 03/16/2001 REFUELING OUTAGE - REACTOR REASSEMBLY IN PROGRESS *  
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 100        
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 22   HOLDING POWER AT THIS LEVEL (WITH THE UNIT ON LINE) TO PERFORM SCRAM TIME TESTING AFTER EXITING A REFUELING OUTAGE *  
MILLSTONE 2 97   HOLDING POWER AT THIS LEVEL TO PERFORM A CIRCULATING WATER BAY OUTAGE *  
MILLSTONE 3 100        
NINE MILE POINT 1 0 03/18/2001 REFUELING OUTAGE - REFUELED *  
NINE MILE POINT 2 95   HOLDING POWER AT THIS LEVEL DUE TO A RECIRCULATION FLOW CONTROL VALVE PROBLEM *  
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 15   UNIT OFF LINE ON 04/21/01 - PERFORMING A TURBINE OVERSPEED TESTING - REFUELING OUTAGE *  
SALEM 1 0 04/06/2001 REFUELING OUTAGE - DEFUELED    
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 0 03/09/2001 REFUELING OUTAGE    
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 0 03/18/2001 REFUELING OUTAGE    
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 0 02/24/2001 REFUELING OUTAGE - FUEL RELOAD IN PROGRESS *  
HARRIS 1 100        
HATCH 1 100        
HATCH 2 100        
MCGUIRE 1 100     *  
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 100        
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 0 02/16/2001 MAINTENANCE OUTAGE    
ROBINSON 2 0 04/06/2001 REFUELING OUTAGE - DEFUELED *  
SAINT LUCIE 1 0 04/02/2001 REFUELING OUTAGE - REFUELED *  
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 0 04/07/2001 REFUELING OUTAGE - DEFUELED    
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 0 04/06/2001 REFUELING OUTAGE *  
CLINTON 1 100        
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 100        
DRESDEN 2 100        
DRESDEN 3 39   HOLDING POWER AT THIS LEVEL TO PERFORM PLANNED RECIRCULATION PUMP SEAL INSPECTIONS AND HEATER WORK *  
DUANE ARNOLD 1 0 04/12/2001 REFUELING OUTAGE - FUEL SHUFFLE IN PROGRESS *  
FERMI 2 100        
KEWAUNEE 1 96   MAXIMUM POWER LEVEL 97% DUE TO PLUGGED STEAM GENERATOR TUBES *  
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 100        
PALISADES 1 0 03/30/2001 REFUELING OUTAGE - FUEL SHUFFLE AND RELOAD COMPLETE - HEAD ON BUT NOT TENSIONED - IN REDUCED INVENTORY TO CHANGE OUT IMPELLER ON PRIMARY COOLANT PUMP *  
PERRY 1 100        
POINT BEACH 1 0 04/06/2001 REFUELING OUTAGE - DEFUELED *  
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100   RIVER LEVEL APPROXIMATELY 18 INCHES BELOW UNUSUAL EVENT EMERGENCY ACTION LEVEL *  
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 0 04/06/2001 REFUELING OUTAGE - DEFUELED *  
COLUMBIA GENERATING 94   COASTDOWN TO REFUELING OUTAGE    
COMANCHE PEAK 1 0 03/24/2001 REFUELING OUTAGE    
COMANCHE PEAK 2 100        
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 0 03/15/2001 REFUELING OUTAGE - REFUELED *  
GRAND GULF 1 0 04/13/2001 REFUELING OUTAGE - FUEL SHUFFLE AND RELOAD IN PROGRESS *  
PALO VERDE 1 0 03/31/2001 REFUELING OUTAGE - DEFUELED    
PALO VERDE 2 100        
PALO VERDE 3 99        
RIVER BEND 1 27   PERFORMING A CHEMISTRY HOLD AFTER EXITING A MAINTENANCE OUTAGE *  
SAN ONOFRE 2 100        
SAN ONOFRE 3 0 02/03/2001 MAINTENANCE OUTAGE    
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WATERFORD 3 100        
WOLF CREEK 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021