Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 49   COASTDOWN TO REFUELING OUTAGE - PERFORMING SAFETY VALVE TESTING PRIOR TO SHUTDOWN *  
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 100        
FITZPATRICK 1 100        
GINNA 1 100     *  
HOPE CREEK 1 100        
INDIAN POINT 2 99     *  
INDIAN POINT 3 100        
LIMERICK 1 100   COASTDOWN TO REFUELING OUTAGE    
LIMERICK 2 100        
MILLSTONE 2 0 02/11/2000 FORCED OUTAGE - REPLACING CDM STACK *  
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 100        
OYSTER CREEK 1 60   HOLDING POWER DUE TO 1 OF 2 MAIN TRANSFORMERS INOPERABLE    
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100     *  
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

To top of page
Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 0 02/13/2000 AUTOMATIC REACTOR TRIP ON TURBINE TRIP DUE TO SUSPECTED ELECTRICAL SHORT IN CONTROL INSTRUMENTATION - SEE EVENT #36686 * 1
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 62   REDUCED POWER DUE TO EXTRACTION STEAM LEAK IN MAIN CONDENSER    
FARLEY 2 100        
HARRIS 1 100        
HATCH 1 100        
HATCH 2 98        
MCGUIRE 1 100        
MCGUIRE 2 97   INCREASING POWER TO 100% *  
NORTH ANNA 1 83   COASTDOWN TO REFUELING OUTAGE    
NORTH ANNA 2 89   HOLDING POWER TO CORRECT PROBLEM WITH THROTTLE VALVE - ROOT VALVE *  
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 86   COASTDOWN TO REFUELING OUTAGE    
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

To top of page
Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 94   COASTDOWN TO REFUELING OUTAGE *  
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 100        
CLINTON 1 100        
COOK 1 0 09/08/1997 REFUELING OUTAGE - DEFUELED    
COOK 2 0 09/09/1997 REFUELING OUTAGE - DEFUELED    
DAVIS BESSE 1 100        
DRESDEN 2 100     *  
DRESDEN 3 100        
DUANE ARNOLD 1 100        
FERMI 2 97        
KEWAUNEE 1 97        
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 0 01/05/2000 REFUELING OUTAGE    
PALISADES 1 0 02/04/2000 SHUTDOWN FOR A PLANNED MAINTENANCE OUTAGE.    
PERRY 1 74   INCREASING POWER TO 100% *  
POINT BEACH 1 100        
POINT BEACH 2 100     *  
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 70   INCREASING POWER TO 100% *  

Region 4

To top of page
Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 0 02/05/2000 SHUTDOWN FOR MAINTENANCE OUTAGE    
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 6   RECOVERING FROM AUTOMATIC REACTOR TRIP DUE TO FAULTY TRANSFORMER PROTECTION IN OFFSITE SWITCHYARD - SEE EVENT #36685 - CURRENTLY WARMING THE MAIN TURBINE * 1
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 100        
PALO VERDE 2 100        
PALO VERDE 3 100        
RIVER BEND 1 100        
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WATERFORD 3 100        
WNP-2 100        
WOLF CREEK 1 93   HOLDING POWER DUE TO LEAK ON LOW PRESSURE HEATER "1B" *  

To top of page

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.