Skip to main content

Power Reactor Status Report for September 26, 1999

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 60   CONDENSER WATERBOX CLEANING    
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 100        
FITZPATRICK 1 55   FEEDWATER PUMP MAINTENANCE *  
GINNA 1 100        
HOPE CREEK 1 100        
INDIAN POINT 2 0 08/31/1999 MAINTENANCE OUTAGE    
INDIAN POINT 3 0 09/10/1999 REFUELING OUTAGE    
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 100     *  
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 88   CONTROL ROD SEQUENCE EXCHANGE *  
OYSTER CREEK 1 100        
PEACH BOTTOM 2 91   INCREASING POWER *  
PEACH BOTTOM 3 80   COASTDOWN TO REFUELING OUTAGE    
PILGRIM 1 100        
SALEM 1 0 09/17/1999 REFUELING OUTAGE *  
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100        
THREE MILE ISLAND 1 0 09/10/1999 REFUELING OUTAGE    
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 100        
BRUNSWICK 1 100     *  
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 76   COASTDOWN TO REFUELING OUTAGE *  
HARRIS 1 100        
HATCH 1 100        
HATCH 2 98   MAXIMUM OPERATING POWER    
MCGUIRE 1 0 09/17/1999 REFUELING OUTAGE    
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 09/11/1999 REFUELING OUTAGE    
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 0 09/24/1999 REFUELING OUTAGE *  
SAINT LUCIE 1 0 09/12/1999 REFUELING OUTAGE    
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100     *  
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 94   COASTDOWN TO REFUELING OUTAGE    
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 100        
CLINTON 1 98     *  
COOK 1 0 09/08/1997 REFUELING OUTAGE - DEFUELED    
COOK 2 0 09/09/1997 REFUELING OUTAGE - DEFUELED    
DAVIS BESSE 1 100        
DRESDEN 2 97   COASTDOWN TO REFUELING OUTAGE *  
DRESDEN 3 100        
DUANE ARNOLD 1 97   COASTDOWN TO REFUELING OUTAGE *  
FERMI 2 97        
KEWAUNEE 1 97        
LASALLE 1 88   COASTDOWN TO REFUELING OUTAGE    
LASALLE 2 100        
MONTICELLO 1 100        
PALISADES 1 100        
PERRY 1 100        
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 75   TURBINE VALVE TESTING *  
QUAD CITIES 1 100        
QUAD CITIES 2 100     *  

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 0 09/10/1999 REFUELING OUTAGE - DEFUELED    
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 93   COASTDOWN TO REFUELING OUTAGE    
COMANCHE PEAK 1 0 09/24/1999 REFUELING OUTAGE *  
COMANCHE PEAK 2 100        
COOPER 1 25   INCREASING POWER *  
DIABLO CANYON 1 75   HOLDING POWER *  
DIABLO CANYON 2 0 09/25/1999 REFUELING OUTAGE *  
FT CALHOUN 1 30   WILL HOLD POWER LEVEL AT 30% UNTIL REFUELING OUTAGE.    
GRAND GULF 1 100        
PALO VERDE 1 100        
PALO VERDE 2 100        
PALO VERDE 3 100        
RIVER BEND 1 100        
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WASHINGTON NUCLEAR 2 0 09/18/1999 REFUELING OUTAGE    
WATERFORD 3 0 09/10/1999 MAINTENANCE OUTAGE    
WOLF CREEK 1 100        

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021