Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for September 5, 1999

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 100        
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 100        
INDIAN POINT 2 0 08/31/1999 FORCED MAINTENANCE OUTAGE    
INDIAN POINT 3 86   COASTDOWN TO REFUELING OUTAGE *  
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 87   HOLDING POWER AT THIS LEVEL TO PERFORM CIRCULATING WATER SYSTEM REPAIRS AND *  
MILLSTONE 3 89   HOLDING POWER AT THIS LEVEL TO PERFORM CONDENSER THERMAL BACKWASHING *  
NINE MILE POINT 1 100        
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100   .    
PEACH BOTTOM 3 87   COASTDOWN TO REFUELING OUTAGE *  
PILGRIM 1 100        
SALEM 1 83   COASTDOWN TO REFUELING OUTAGE    
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100        
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 97   COASTDOWN TO REFUELING OUTAGE    
HARRIS 1 100        
HATCH 1 100        
HATCH 2 98        
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 87   COASTDOWN TO REFUELING OUTAGE *  
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 91   COASTDOWN TO REFUELING OUTAGE    
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 100        
CLINTON 1 80   HOLDING POWER AT THIS LEVEL TO PERFORM TURBINE VALVE TESTING *  
COOK 1 0 09/08/1997 REFUELING OUTAGE - DEFUELED    
COOK 2 0 09/09/1997 REFUELING OUTAGE - DEFUELED    
DAVIS BESSE 1 100        
DRESDEN 2 100        
DRESDEN 3 100        
DUANE ARNOLD 1 63   HOLDING POWER AT THIS LEVEL TO PERFORM COOLING TOWER REPAIRS *  
FERMI 2 97        
KEWAUNEE 1 97        
LASALLE 1 22   HOLDING POWER AT THIS LEVEL (ON LINE) TO PERFORM SURVEILLANCE TESTING AFTER *  
LASALLE 2 100        
MONTICELLO 1 100        
PALISADES 1 100        
PERRY 1 100        
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 100        
PALO VERDE 2 100     *  
PALO VERDE 3 75   HOLDING POWER AT THIS LEVEL TO PERFORM FEEDWATER PUMP MAINTENANCE    
RIVER BEND 1 90   INCREASING POWER AFTER DECREASING TO 60% TO PERFORM FLUX SUPPRESSION TESTING *  
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WASHINGTON NUCLEAR 2 77   COASTDOWN TO REFUELING OUTAGE *  
WATERFORD 3 100        
WOLF CREEK 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021