Power Reactor Status Report for May 17, 1999
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BEAVER VALLEY 1 | 62 | HOLDING POWER AT THIS LEVEL TO PERFORM PLANNED MAINTENANCE ON A FEEDWATER PU | * | ||
| BEAVER VALLEY 2 | 100 | ||||
| CALVERT CLIFFS 1 | 0 | 05/10/1999 | MAINTENANCE OUTAGE | * | |
| CALVERT CLIFFS 2 | 100 | ||||
| FITZPATRICK 1 | 100 | ||||
| GINNA 1 | 98 | OPERATING AT REDUCED LOAD DUE TO DELTA-T SETPOINT ISSUES | * | ||
| HOPE CREEK 1 | 100 | ||||
| INDIAN POINT 2 | 99 | MAXIMUM OPERATING POWER DUE TO STEAM FLOW DEMAND - TURBINE THROTTLE VALVES F | |||
| INDIAN POINT 3 | 63 | HOLDING POWER AT THIS LEVEL DUE TO A HEATER DRAIN TANK PUMP TRIP | * | ||
| LIMERICK 1 | 100 | ||||
| LIMERICK 2 | 0 | 04/16/1999 | REFUELING OUTAGE - REACTOR VESSEL HEAD IN PLACE BUT NOT TENSIONED | * | |
| MILLSTONE 2 | 63 | INCREASING POWER TO 75% FOR AN NRC HOLD | * | ||
| MILLSTONE 3 | 0 | 05/01/1999 | REFUELING OUTAGE - FUEL OFFLOAD SUSPENDED DUE TO PROBLEMS WITH SIGMA MACHINE | ||
| NINE MILE POINT 1 | 0 | 04/11/1999 | REFUELING OUTAGE - DEFUELED | ||
| NINE MILE POINT 2 | 100 | ||||
| OYSTER CREEK 1 | 100 | * | |||
| PEACH BOTTOM 2 | 100 | ||||
| PEACH BOTTOM 3 | 100 | ||||
| PILGRIM 1 | 0 | 05/08/1999 | REFUELING OUTAGE - FIRST PHASE OF FUEL SHUFFLE COMPLETE | * | |
| SALEM 1 | 100 | ||||
| SALEM 2 | 0 | 04/03/1999 | REFUELING OUTAGE | ||
| SEABROOK 1 | 89 | INCREASING POWER AFTER EXITING A REFUELING OUTAGE | * | ||
| SUSQUEHANNA 1 | 100 | ||||
| SUSQUEHANNA 2 | 100 | ||||
| THREE MILE ISLAND 1 | 100 | ||||
| VERMONT YANKEE 1 | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BROWNS FERRY 1 | 0 | 03/03/1985 | DEFUELED | ||
| BROWNS FERRY 2 | 60 | INCREASING POWER AFTER RECOVERING FROM AN AUTOMATIC TURBINE TRIP/REACTOR SCR | * | ||
| BROWNS FERRY 3 | 100 | ||||
| BRUNSWICK 1 | 100 | ||||
| BRUNSWICK 2 | 0 | 04/16/1999 | REFUELING OUTAGE | ||
| CATAWBA 1 | 0 | 04/21/1999 | REFUELING OUTAGE | ||
| CATAWBA 2 | 0 | 05/03/1999 | MAINTENANCE OUTAGE - EXPERIENCING GENERATOR PROBLEMS | * | |
| CRYSTAL RIVER 3 | 100 | ||||
| FARLEY 1 | 100 | ||||
| FARLEY 2 | 100 | ||||
| HARRIS 1 | 100 | ||||
| HATCH 1 | 97 | HOLDING POWER AT THIS LEVEL TO PERFORM POWER UPRATE TESTING | |||
| HATCH 2 | 98 | MAXIMUM OPERATING POWER | |||
| MCGUIRE 1 | 100 | ||||
| MCGUIRE 2 | 100 | ||||
| NORTH ANNA 1 | 100 | ||||
| NORTH ANNA 2 | 100 | ||||
| OCONEE 1 | 100 | ||||
| OCONEE 2 | 100 | ||||
| OCONEE 3 | 50 | INCREASING POWER AFTER EXITING A FORCED MAINTENANCE OUTAGE DUE TO LOW REACTO | * | ||
| ROBINSON 2 | 100 | ||||
| SAINT LUCIE 1 | 100 | ||||
| SAINT LUCIE 2 | 100 | ||||
| SEQUOYAH 1 | 100 | ||||
| SEQUOYAH 2 | 100 | ||||
| SUMMER 1 | 73 | HOLDING POWER AT THIS LEVEL TO PERFORM FLUX MAPPING AFTER EXITING A REFUELIN | |||
| SURRY 1 | 100 | ||||
| SURRY 2 | 0 | 04/18/1999 | REFUELING OUTAGE | ||
| TURKEY POINT 3 | 100 | ||||
| TURKEY POINT 4 | 100 | ||||
| VOGTLE 1 | 100 | ||||
| VOGTLE 2 | 100 | ||||
| WATTS BAR 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BRAIDWOOD 1 | 100 | LOAD REDUCED TO 15% ON 05/16/99 DUE TO A TECH SPEC REQUIRED SHUTDOWN RESULTI | * | ||
| BRAIDWOOD 2 | 0 | 04/23/1999 | REFUELING OUTAGE | ||
| BYRON 1 | 0 | 05/13/1999 | AUTOMATIC REACTOR TRIP FROM 100% POWER DUE TO AN INADVERTENT POWER RANGE HIG | * | |
| BYRON 2 | 100 | ||||
| CLINTON 1 | 0 | 05/14/1999 | REFUELING OUTAGE - MANUAL REACTOR SCRAM FROM 4% POWER DUE TO A LEVEL TRANSIE | ||
| COOK 1 | 0 | 09/08/1997 | MAINTENANCE OUTAGE | ||
| COOK 2 | 0 | 09/09/1997 | REFUELING OUTAGE | ||
| DAVIS BESSE 1 | 100 | ||||
| DRESDEN 2 | 100 | * | |||
| DRESDEN 3 | 99 | * | |||
| DUANE ARNOLD 1 | 100 | ||||
| FERMI 2 | 97 | ADMINISTRATIVE POWER LIMIT | |||
| KEWAUNEE 1 | 97 | POWER LIMITED DUE TO STEAM GENERATOR TUBE PLUGGING | |||
| LASALLE 1 | 100 | ||||
| LASALLE 2 | 100 | ||||
| MONTICELLO 1 | 0 | 05/08/1999 | MAINTENANCE OUTAGE | ||
| PALISADES 1 | 0 | 05/07/1999 | MAINTENANCE OUTAGE - AT NORMAL OPERATING TEMPERATURE AND PRESSURE | * | |
| PERRY 1 | 100 | ||||
| POINT BEACH 1 | 0 | 05/14/1999 | MANUAL REACTOR TRIP FROM 100% POWER AND MANUAL SAFETY INJECTION DUE TO A STE | ||
| POINT BEACH 2 | 30 | HOLDING POWER AT THIS LEVEL FOLLOWING INSPECTION OF THE #4 FEEDWATER HEATERS | * | ||
| PRAIRIE ISLAND 1 | 0 | 04/16/1999 | REFUELING OUTAGE - REACTOR VESSEL HEAD ON AND TENSIONED - PREPARING FOR FILL | * | |
| PRAIRIE ISLAND 2 | 100 | ||||
| QUAD CITIES 1 | 100 | ||||
| QUAD CITIES 2 | 100 |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| ARKANSAS NUCLEAR 1 | 100 | ||||
| ARKANSAS NUCLEAR 2 | 100 | ||||
| CALLAWAY 1 | 100 | ||||
| COMANCHE PEAK 1 | 100 | ||||
| COMANCHE PEAK 2 | 100 | ||||
| COOPER 1 | 100 | ||||
| DIABLO CANYON 1 | 100 | ||||
| DIABLO CANYON 2 | 100 | ||||
| FT CALHOUN 1 | 100 | ||||
| GRAND GULF 1 | 100 | ||||
| PALO VERDE 1 | 100 | ||||
| PALO VERDE 2 | 100 | ||||
| PALO VERDE 3 | 100 | ||||
| RIVER BEND 1 | 0 | 04/03/1999 | REFUELING OUTAGE - PLAN TO RECOMMENCE FUEL SHUFFLE ON DAY SHIFT | * | |
| SAN ONOFRE 2 | 100 | ||||
| SAN ONOFRE 3 | 60 | INCREASING POWER AFTER RECOVERING FROM A MANUAL REACTOR TRIP FROM 24% POWER | * | ||
| SOUTH TEXAS 1 | 12 | UNIT ON LINE AND INCREASING POWER AFTER RECOVERING FROM AN AUTOMATIC REACTOR | * | 1 | |
| SOUTH TEXAS 2 | 100 | ||||
| WASHINGTON NUCLEAR 2 | 0 | 04/17/1999 | MAINTENANCE OUTAGE | ||
| WATERFORD 3 | 93 | DECREASING TO 90% POWER TO PERFORM WORK ON A MAIN TURBINE GOVERNOR VALVE | * | ||
| WOLF CREEK 1 | 100 |