Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for April 25, 1999

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 0 04/12/1999 MAINTENANCE OUTAGE    
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 0 03/12/1999 REFUELING OUTAGE    
FITZPATRICK 1 100        
GINNA 1 61   HOLDING FOR OFFSITE ELECTRICAL WORK *  
HOPE CREEK 1 100        
INDIAN POINT 2 99   MAXIMUM OPERATING POWER DUE TO TURBINE CONTROL VALVE POSITION    
INDIAN POINT 3 100        
LIMERICK 1 4   HOLDING TO PUT OFFGAS SYSTEM ON LINE *  
LIMERICK 2 0 04/16/1999 REFUELING OUTAGE    
MILLSTONE 2 0 02/20/1996 MAKING PREPARATION TO GO TO MODE 3 *  
MILLSTONE 3 99   INCREASING POWER AFTER THERMAL BACKWASH OF CONDENSER *  
NINE MILE POINT 1 0 04/11/1999 REFUELING OUTAGE    
NINE MILE POINT 2 0 04/23/1999 MAINTENANCE OF EQUIPMENT CAUSING ELECTRICAL TRANSIENT *  
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 80   INOPERABLE MAIN STEAM ISOLATION VALVE    
SALEM 1 100        
SALEM 2 0 04/03/1999 REFUELING OUTAGE - DEFUELED    
SEABROOK 1 0 03/27/1999 REFUELING OUTAGE - DEFUELED    
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 1   HOLDING FOR TEST *  
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 0 04/11/1999 REFUELING OUTAGE    
BROWNS FERRY 3 100     *  
BRUNSWICK 1 100        
BRUNSWICK 2 0 04/16/1999 REFUELING OUTAGE - DEFUELING IN PROGRESS    
CATAWBA 1 0 04/21/1999 ENTERING REFUELING OUTAGE    
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 50   OPERATING AT REDUCED POWER TO AVOID COASTDOWN DURING PEAK DEMAND PERIOD    
HARRIS 1 100        
HATCH 1 1   HOLDING FOR SRM PROBLEM *  
HATCH 2 98   MAXIMUM OPERATING POWER    
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 100        
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 0 04/18/1999 REFUELING OUTAGE    
SUMMER 1 0 04/03/1999 REFUELING OUTAGE - DEFUELED    
SURRY 1 100        
SURRY 2 0 04/18/1999 REFUELING OUTAGE    
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 0 04/23/1999 REFUELING OUTAGE *  
BYRON 1 15   PREPARATIONS FOR PUTTING GENERATOR BACK ON LINE *  
BYRON 2 100        
CLINTON 1 0 09/06/1996 REFUELING OUTAGE    
COOK 1 0 09/08/1997 MAINTENANCE OUTAGE    
COOK 2 0 09/09/1997 REFUELING OUTAGE    
DAVIS BESSE 1 0 04/23/1999 PLANNED MID CYCLE MAINTENANCE OUTAGE. *  
DRESDEN 2 100     *  
DRESDEN 3 91   REDUCED POWER FOR TURBINE CHECK *  
DUANE ARNOLD 1 0 04/17/1999 MAINTENANCE OUTAGE    
FERMI 2 97   MAXIMUM POWER LEVEL    
KEWAUNEE 1 98        
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 0 04/22/1999 MINI OUTAGE - REPAIR DIGITAL FEEDWATER CONTROL SYSTEM    
PALISADES 1 100        
PERRY 1 0 03/26/1999 REFUELING OUTAGE    
POINT BEACH 1 0 04/22/1999 MAINTENANCE OUTAGE IN PROGRESS    
POINT BEACH 2 100        
PRAIRIE ISLAND 1 0 04/16/1999 REFUELING OUTAGE    
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 0 04/09/1999 MAINTENANCE OUTAGE    
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 47   INCREASING POWER *  
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 85   REDUCING POWER TO 50% FOR PLANNED CLEANING OF CIRC WATER SYSTEM *  
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 100        
PALO VERDE 2 0 03/26/1999 REFUELING OUTAGE - CORE RELOAD IN PROGRESS    
PALO VERDE 3 99     *  
RIVER BEND 1 0 04/03/1999 REFUELING OUTAGE    
SAN ONOFRE 2 100        
SAN ONOFRE 3 0 03/27/1999 REFUELING OUTAGE *  
SOUTH TEXAS 1 0 03/26/1999 REFUELING OUTAGE    
SOUTH TEXAS 2 100        
WASHINGTON NUCLEAR 2 0 04/17/1999 MAINTENANCE OUTAGE    
WATERFORD 3 100        
WOLF CREEK 1 0 04/03/1999 REFUELING OUTAGE - RELOADING FUEL    