Part 21 Report - 1999-321
ACCESSION #: 9907140159
Shared Services Group
P.O. box 3707
Seattle, WA 98124-2207
July 7, 1999
G-1151 -SJA-98-301
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
| Reference: | a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center |
| b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry |
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
| Very truly yours, Sandra J. Andrews |
Enclosure(s): GTSTRUDL Program Report Form 99.14 & 99.15
| Georgia Institute of Technology | GT STRUDL "Register mark" |
June 30, 1999
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 99.14 and 99.15, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgement Form.
Best regards,
CASE Center
David C. Key
Configuration Control Manager
Enclosures
Computer Aided Structural Engineering Center School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA
Phone: (404) 894-2260
Fax: (404) 894-8014
casec@ce.gatech-edu
| A Unit of the University System of Georgia | GTSTRUDL Program Report Form |
GPRF No.: 99.14
DATE:
FROM:
Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
-URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
-SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
x MINOR Problem can be worked around or problem poses high frustration factor.
-INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed June 21, 1999
Date Notification Sent
Computers All
Operating System All
Versions: 97.01 and 98.01
Target Release for Correction: 99.02
Mgr. ASD
Signature Title
R & D Division
Michael H. Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
GPRF No.: 99.14
DATE:
DESCRIPTION:
Deletion of a rigid body erroneously inactivates any of the rigid body incident joints to which only one additional conventional member or finite element is attached. A message of the following syntax is printed when this condition is encountered:
****INFO_STMJDL -- THE FOLLOWING JOINTS WERE MADE INACTIVE WHEN THE ABOVE MEMBERS WERE DELETED 601 602 901 902
The problem cannot be avoided; however, the joints identified in the message can re-activated using the ACTIVE command.
Applicable Reference Manual Sections
1. Joint Constraints - Joint Ties and Rigid Bodies Section 2.6.4, Volume 3, GTSTRUDL Reference Manual
2. ACTIVE/INACTIVE Structure Specification Section 2.1.3.4, Volume 1, GTSTRUDL Reference Manual
Rev. 2. 2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM:
Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
-SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
-MINOR Problem can be worked around or problem poses high frustration factor.
-INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers SUN, PC
Operating System SUN OS, Windows NT/95/98
Versions 9601 SPARC, 9701NT, and 9801NT
Target Release for Correction 9901
Director ASD
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2.
GTSTRUDL Program Report Form (Continued)
GPRF No.:
DATE:
DESCRIPTION:
Member elastic end connection data may be stored incorrectly if the units are not inches and pounds. This error does not always occur and is dependent on the sequence of commands which preceded the MEMBER RELEASE command with the elastic connection data.
The user can verify that the elastic connection data has been stored correctly by issuing the PRINT MEMBER RELEASE command.
Workaround:
Always input the elastic connection data in inches and pounds or specify the MEMBER RELEASE data with elastic connections at the beginning of the input data before any other data has been specified.
Applicable Section of the Users Manual:
Section 2.1.8.2 of Volume 1 - MEMBER RELEASES Command
Section 2.1.14.2 of Volume 1 - PRINT MEMBER RELEASES Command
Rev. 2-2
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021