Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1997-842

ACCESSION #: 9712300095 Paul H. Kinkel Vice President Consolidated Edison Company of New York, Inc. Indian Point Station Broadway & Bleakley Avenue Buchanan, NY 10511 Telephone (914) 734-5340 Fax: (914) 734-5923 December 17, 1997 Re: Indian Point Unit No. 2 Docket No. 50-247 Document Control Desk US Nuclear Regulatory Commission Mail Station P1-137 Washington, DC 20555 SUBJECT: 10 CFR Part 21 Written Notification On November 17, 1997, Con Edison submitted, by facsimile, the initial notification of a condition at Indian Point Unit No. 2 which we determined to be reportable under the requirements of 10 CFR Part 21. The reported condition involved a defect in environmentally qualified Motor Operated Valves which had been installed at the plant. Subsequent to that initial notification, we have learned of further test data that appears to conclude that the MOVs were operable regardless of the defect. However, since we have not yet fully analyzed this test data and determined that we are in full agreement with the conclusion based on that data, we are conservatively submitting this report under Part 21. The requirements of 10 CFR 21.21 (d)(4) identify specific information to be included in this written notification. That information is provided in the attachment to this letter. Should you have any questions regarding this matter, please contact Mr. Charles W. Jackson, Manager, Nuclear Safety and Licensing. Very truly yours, C: Mr. Hubert J. Miller Regional Administrator - Region I US Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Jefferey F. Harold, Project Manager Project Directorate I-1 Division of Reactor Projects I/II US Nuclear Regulatory Commission Mail Stop 14B-2 Washington, DC 20555 Senior Resident Inspector US Nuclear Regulatory Commission PO Box 38 Buchanan, NY 10511 ATTACHMENT Indian Point Unit No. 2 - Defective MOV T-Drains The following information is provided as required by 10 CFR 21.21 (d)(4). (i) Name and address of individual informing the Commission. Paul Kinkel, Vice President - Nuclear Power Consolidated Edison Company of New York, Inc. Indian Point Unit No. 2 Broadway and Bleakley Ave. Buchanan, NY 10511 (ii) Identification of the basic component which contains a defect. Component: Motor Operator Model: SB-00-25; SMB-00-25; SMB-00-15; SMB-00; SMB-000 (iii) Identification of the firm supplying the basic component which contains a defect. Limitorque Corporation, Lynchburg, VA (iv) Nature of the defect and the safety hazard which could be created by such a defects. T-drain not drilled through vertically and would act as a pipe plug. Condensation buildup inside the motor would not be relieved resulting in possible degraded motor performance. BACKGROUND (v) The date on which the information of such defect was obtained. Concerns regarding the quality of the Limitorque T-Drains were raised initially on May 21, 1997. In accordance with Company procedures, a determination that this component may fall in the scope of Part 21 was made on September 15, 1997 and a formal evaluation commenced. The evaluation was completed on November 17, 1997 and communicated by facsimile under Part 21 on that day. (vi) In the case of a basic component which contains a defect, the number and location of all such components in use at the facility subject to the regulations in this part. Seven total, four located in the Primary Auxiliary Building and three located in containment. (vii) The corrective action which has been taken. The improperly drilled T-drains were replaced with correctly drilled T-drains. (viii) Any advice related to the defect that has been given to purchasers or licensees. Informal discussions with several licensees. *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021